P01.20-0231-06
1 Torx bolt
2 Cylinder head cover
3 Shaped rubber gasket
4 Clamp
5 Crankcase ventilation line
6 CMP sensor connector
| Remove/install | ||
1 | Remove induction module | ||
2 | Separate camshaft position sensor connector (6) | ||
3 | Detach engine breather pipe (5) at cylinder head cover (2) | Inspect condition of collar clamp (4), replace if necessary | |
4 | Take off air pump switchover valve at cylinder head cover | ||
5 | Detach cylinder head cover (2) at cylinder head and take off together with rubber gasket (3) | Inspect condition of shaped rubber gasket (3), replace if necessary. Clean sealing surfaces. | |
Installation: Pay attention to tightening diagram of cylinder head cover (2) | |||
| |||
6 | Install in the reverse order |
Crankcase ventilation, cylinder head cover
Referenced documents
- ar0120l501403vb Bolt tightening diagram for cylinder head cover
- ar0920l1400vb Removal/installation of intake module
- ar1430p7255gf Removing/installing the air pump switchover valve