AR01.00-G-0200B | Inspect cylinders with a light probe | 9.1.12 |
ENGINES 900.915 /916 /920 /921, 902.923 /924 /935, 904.927 /928 /952 /953, 906.935 /955, 924.916 /923 /931, 926.969
W01.00-0018-06
1 Test probe
2 Endoscope
| Remove/install | ||
1 | Attach turning device for engine | ||
| |||
Turning device | |||
2 | Remove nozzle holder combination | ||
3 | Rotate crankshaft with cranking device | Position piston of cylinder to be inspected to BDC. | |
4 | Connect test probe (1) to endoscope (2) | Observe operating instructions from equipment manufacturer. | |
5 | Insert inspection probe (1) through protective sleeve hole into cylinder | ||
| Checking | ||
6 | Inspect cylinder wall and piston crown | Cylinder walls must not have any scorch streaks and rubbing streaks. Individual slight scores are not critical. Inspect condition of piston crown, if necessary: | |
Remove cylinder head | |||
| Notes for assessing wear to cylinder wall in the case of dust damage | ||
7 | Inspect remaining cylinders in the same way | ||
8 | Install in the reverse order |
Timing case
Number | Designation | Engine | |
BA01.60-N-1002-01J | Inspection hole closure cover to timing case | Nm | 25 |
904 589 04 63 00
Cranking device
Referenced documents
- ah0140n000101a Notes for assessing wear to cylinder wall in the case of dust damage
- ar0130g5800b Remove/install cylinder head
- ar0330g160003b Attach/detach cranking/blocking device for engine
- ar0703g6831b Remove/install nozzle holder combination