Check cover in area of roof air conditioner evaporator unit for traces of water
Type ap · topic 68.00 · version 0200 · 2016-12-20
Applies to: Model 906.6/7 with code H08 (Roof-mounted air conditioning system, reinforced) Model 906.6/7 with code HH0 (Air conditioning parts kit) with code HH5 (Air conditioning preinstallation) Model 906.6/7 with code HH7 (Roof-mounted air conditioning system, basic)
Where it sits
Function group 3 Body › 68 Interior equipment › 68.00 General — Series 906 (models 6**, 7**)
EinPAS 37 Interior equipment › 37.45 Trim › 37.45.30 Vehicle interior/passenger compartment trim — Series 906 (models 6**, 7**)
EinPAS 37 Interior equipment › 37.45 Trim › 37.45.31 Door trim — Series 906 (models 6**, 7**)
AP68.00-D-0001US
Check cover in area of roof air conditioner evaporator unit for traces of water
16.12.2016
Model
906.6/7
with code H08 (Roof-mounted air conditioning system, reinforced)
Model
906.6/7
with code HH0 (Air conditioning parts kit)
with code HH5 (Air conditioning preinstallation)
Model
906.6/7
with code HH7 (Roof-mounted air conditioning system, basic)
16.12.2016
Reference to LI83.50-N-064932 changed, was LI83.50N064837
Operation step 2
Defined area (colored yellow) for visual inspection
Example for discolorations
Example for drops of water
Visual inspection (in yellow colored area)
1
Check headliner in area of 20.5 cm / 8 inch spacing to paneling of evaporator unit for drops of water and any discolorations
If drops of water or discolorations are determined
Open TIPS case and conduct repair work in accordance with LI83.50N059306. Replace damaged parts of headliner.
2
Check air intake grille and air vents for traces of water (water drops)
If water drops are detected
Open TIPS case and conduct repair work in accordance with LI83.50N059306 and LI83.50064932. Replace damaged parts of headliner.
Note service information on condensate formation on paneling surface of evaporator unit.
SI83.50-D-0001BM
Referenced documents
si8350d0001bm Service Information: Condensation formation on surface of cover of evaporator
unit (roof air conditioner)