ap4200w4293c

Read out brake wear in display

Type ap · topic 42.00 · version 0104 · 2019-07-23

Applies to: Model 930, 932, 933, 934

Where it sits

Function group 2 Chassis › 42 Brakes - hydraulic and mechanical systems › 42.00 General — Series 930 · Series 932 · Series 933 · Series 934

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.15 Service brake/vacuum system › 21.15.5 Brake system, complete — Series 930 · Series 932 · Series 933 · Series 934

AP42.00-W-4293C

Read out brake wear in display

22.07.2019

Model

930, 932, 933, 934

Read out brake wear in display

1

Pushbutton

2

Pushbutton

3

Pushbutton

4

Pushbutton

5

Pushbutton

6

Pushbutton

7

Multifunction display

N54.30-8274-11

1

Move steering lock to drive position

2

Call up "Adjustments" menu by repeatedly pressing the button (3 or 4).

3

Position the visual bar on the "Configuration" menu by repeatedly pressing button (1 or 2).

4

Press button (5 or 6) until the "Enable diagnosis" menu is displayed and open the diagnosis menu by pressing button (1).

5

Call up the "Diagnosis" menu by pressing button (4).

6

By pressing the button (1 or 2) select the "Diagnosis" submenu and confirm with button (5).

7

Press button (1 or 2) to select "FM" control unit from list of control units shown, and confirm with button (5)

8

By repeatedly pressing the button (1 or 2) select the "Measurement values" menu and confirm with button (5)

9

Repeatedly pressing the button (1 or 2 ) enables the measurement values (MV) MV 2 to MV 5 to be read out in the multifunction display (7)

Do not actuate the service brake during the read out process.

10

Enter the read out test values on the maintenance sheet.

Axle assignment of brake lining sensors

AH42.10-N-1007-01A

11

Secure vehicle against rolling

12

Release parking brake

13

Press button (6) repeatedly until the list of control units is shown

14

By repeatedly pressing the button (1 or 2) select the "HM" control unit and confirm with button (5)

15

By repeatedly pressing the button (1 or 2) select the "Measurement values" menu and confirm with button (5)

16

Repeatedly pressing the button (1 or 2 ) enables the measurement values MV 2 to MV 5 to be read out in the multifunction display (7)

Do not engage parking brake and service brake when reading out.

17

Enter the read out test values on the maintenance sheet.

Axle assignment of brake lining sensors

AH42.10-N-1007-01A

18

Return to the main menu by pressing key (3 or 4) repeatedly.

Referenced documents