AP32.31-M-0100A | Check/correct oil level in hydraulic lowering system | 21.3.07 |
MODEL 905.613
Minibus Sprinter low floor 6 t,
with hydraulic lowering system on front axle
M68.30-0009-11
1 Cover
2 Floor panel
M32.31-0009-11
3 Cap
4 Reservoir
5 Hydraulic pump
| Remove/install | ||
Danger! | Risk of injury to skin or eyes caused by hydraulic fluid spraying out under high pressure. Risk of poisoning caused by swallowing hydraulic fluid. | Depressurize the hydraulic system completely before starting any work on the system. Wear protective clothing and safety glasses. | |
1 | Remove cover (1) of additional battery | ||
2 | Remove floor panel (2) | ||
| Checking | ||
3 | Check hydraulic fluid level in reservoir (4) | Observe marking on dipstick of threaded connection of reservoir (4). | |
4 | Pour hydraulic fluid into reservoir (4) | Only carry out when the hydraulic fluid level is too low. | |
Only the hydraulic fluid "Shell Donax TM" may be used which is listed in sheet 236.2. | |||
| Automatic transmission fluids (ATF, type A, suffix A) | Sheet 236.2 | |
5 | Bleed hydraulic lowering system | Out the hydraulic lowering system into operation and lower and raise the vehicle several times. | |
6 | Check hydraulic fluid level in the reservoir (4) again and correct if necessary | For this purpose carry out operation step 3 and if necessary steps 4 and 5 repeatedly. | |
7 | Install in the reverse order |
Referenced documents
- as0000z001301a Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid.
- bb0040p023602a Automatic transmission fluids (ATF), type A, suffix A (specification 236.2)