AP28.80-M-2811A | Reversing gear - check, correct oil level | 7.9.04 |
TRANSFER CASE 612.700 in MODEL 904.663
Minibus Sprinter low floor
TRANSFER CASE 612.700 in MODEL 905.613
Minibus Sprinter low floor 6 t
M28.80-0002-02
1 Oil filler screw
| Check | ||
1 | Check reversing gear for leaks | Sealing points which weep slightly are safe. Eliminate leakage immediately - subject to a separate repair order. | |
2 | Clean the are around the oil filler screw (1) | ||
3 | Remove oil filler screw (1) | The oil level is correct when the oil is at the bottom edge of the oil filler opening. Correct the oil level if necessary. | |
| |||
| Hypoid gear oils | SAE 75 W-90 (full synthetic) | |
4 | Screw in oil filler screw (1) | |
Reversing gear
Reversing gear
Referenced documents
- bb0040p023508a Hypoid gear oils SAE 75 W-90 (specification 235.8)