ap2000s201002ps

Calculate top-up quantity of anti-corrosion agent and antifreeze

Type ap · topic 20.00 · version 0100 · 2018-06-22

Applies to: Engine 642.8 in model 470, 471

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.00 General — Series 470 · Series 471

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.5 Coolant circuit, complete — Series 470 · Series 471

Also applies to engines/gearboxes: 642 8**

AP20.00-S-2010-02PS

Calculate top-up quantity of anti-corrosion agent and antifreeze

Engine

642.8 in model 470, 471

Filling capacities for engine cooling system

Number

Designation

Engine 642 in model 470, 471

BF20.00-N-1001-01PS

Coolant

Total filling capacity

Liter

 10,0

Anti-corrosion protection/antifreeze down to ­37 °C

Liter

 5,0

Anti-corrosion protection/antifreeze down to ­45 °C

Liter

 5,5

Sheet

BB00.40-P-0310-01A

Sheet

BB00.40-P-0325-05A

Sheet

BB00.40-P-0326-06A

Table of comparison (approx.) antifreeze protection to anticorrosion and antifreeze additive concentration (A)

°C

vol %

°C

vol %

°C

vol %

-10

20

-20

32

-30

42

-15

26

-25

37

-33

45

-18

30

-27

40

-37

50

Calculate top-up quantity of anti-corrosion agent and antifreeze

Formula for calculation of top-up quantity for anticorrosion and antifreeze agent (C)

A

Anticorrosion agent concentration and antifreeze concentration (in % by volume)

B

Total quantity of coolant (in liters)

C

Top-up quantity for anticorrosion and antifreeze agent (in liters)

N20.00-0377-04

Calculate top-up quantity of anti-corrosion agent and antifreeze

Example calculation

N20.00-2001-04

Example calculation

Measured antifreeze protection -20 °C, equivalent to 32 % by volume anticorrosion and antifreeze additive concentration (A).

Total coolant capacity (B) = 8.5 l.

Required top-up quantity for anticorrosion and antifreeze agent (C) = 2.25 l.

1

Enter determined anticorrosion and antifreeze protection concentration (A) into formula.

2

Take total coolant fill quantity (B) from   the basic data table and enter into the formula.

3

Calculate required top-up quantity for anticorrosion and antifreeze agent (C).