ad8370w6000e

Auxiliary heater (AHE) test of electrical system

Type ad · topic 83.70 · version 0100 · 2003-06-16

Applies to: MODEL 625.1 /2, 655, 656, 657, 658, 659 with CODE (H08) Hot water auxiliary heater D 5 W with CODE (E06) Electrical system - German road transport regulations for hazardous materials (GGVS) MODEL 650, 651, 652, 653, 654 with CODE (H08) Hot water auxiliary heater D 5 W with CODE (E06) Electrical system - German road transport regulations for hazardous materials (GGVS)

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 625 (models 1**, 2**) · Series 650 · Series 651 · Series 652 · Series 653 · Series 654 · Series 655 · Series 656 · Series 657 · Series 658 · Series 659

AD83.70-W-6000E

Auxiliary heater (AHE) test of electrical system

5.2.98

MODEL 625.1 /2, 655, 656, 657, 658, 659
with CODE (H08) Hot water auxiliary heater D 5 W
with CODE (E06) Electrical system - German road transport regulations for hazardous materials (GGVS)

MODEL 650, 651, 652, 653, 654
with CODE (H08) Hot water auxiliary heater D 5 W
with CODE (E06) Electrical system - German road transport regulations for hazardous materials (GGVS)

Auxiliary heater (AHE) diagnosis, previous knowledge

AD83.70-W-2000E

Auxiliary heater (AHE), location of components

GF83.70-W-0003-03E

Auxiliary heater diagnostic tools

AD83.70-W-2000-02C

Do not carry out measurements at contact points of plug connections with unsuitable equipment (test probes, wire ends etc.). Always use appropriate test cables from connection set (201 589 00 99 00).

Cables, plug connections and fuses are included in the following tests.

Details of cable / cable colors, fuses and component installation locations in the following test instructions are valid only for vehicles with factory-fitted special equipment, auxiliary heater D5W. If heater unit is retrofitted and a third party (e.g. drivers, customers) have made alterations / manipulations or non-specialist repairs have been made, the following test program may only be of limited use. The same applies to wiring diagram.

Corresponding test steps may be used for troubleshooting on retrofitted auxiliary heaters the . Only heater unit components, control unit or operating unit(s) can be correctly diagnosed as fault sources. Faults in cabling etc. must be found manually using relevant wiring diagram (e.g. from Eberspächer).

a

On-board voltage 22.5-29.5V

b

Connect Hand-Held Tester (HHT)

AD00.00-W-2000-03A

Test

1

Generator charging voltage, testing electrical system of AHE

AD83.70-W-6000-18B

2

Battery voltage, testing electrical system of AHE

AD83.70-W-6000-19B

3

Auxiliary heater control unit overvoltage shutoff, testing electrical system of AHE

AD83.70-W-6000-20B

4

Auxiliary heater control unit undervoltage shutoff, testing electrical system of AHE

AD83.70-W-6000-21B

5

Open-circuit in metering pump, temperature-controlled cutout, control unit circuit, testing electrical system of AHE

AD83.70-W-6000-22C

6

Glow plug, testing electrical system of auxiliary heater

AD83.70-W-6000-09B

7

Diagnostic cable, testing electrical system of auxiliary heater

AD83.70-W-6000-04B

8

Combustion air blower, testing electrical system of AHE

AD83.70-W-6000-46C

9

Short-circuit to ground combustion air blower, testing electrical system of AHE

AD83.70-W-6000-24B

10

Open-circuit in partial load relay circuit, testing electrical system of AHE

AD83.70-W-6000-25B

11

Short-circuit to ground in partial load relay, testing electrical system of AHE

AD83.70-W-6000-26B

12

Coolant circulation pump, testing electrical system of AHE

AD83.70-W-6000-27A

13

Fuel metering pump, testing electrical system of auxiliary heater

AD83.70-W-6000-10C

14

Flame monitor, testing electrical system of auxiliary heater

AD83.70-W-6000-13B

15

Open-circuit in temperature sensor circuit, testing electrical system of AHE

AD83.70-W-6000-29C

16

Open-circuit in flame monitor and temperature sensor circuit, testing electrical system of AHE

AD83.70-W-6000-47B

17

Short-circuit to ground in temperature sensor, testing electrical system of AHE

AD83.70-W-6000-30B

18

Open-circuit in flame monitor circuit, testing electrical system of AHE

AD83.70-W-6000-37C

19

Short-circuit to ground in flame monitor, testing electrical system of AHE

AD83.70-W-6000-36C

20

Auxiliary heater switch, testing electrical system of AHE

AD83.70-W-6000-71A

21

PTO indicator lamp, testing electrical system of power take-off

AD26.45-W-6000-02B

22

PTO pressure switch, testing electrical system of power take-off

AD26.45-W-6000-01B

23

Auxiliary heater control unit cables, testing electrical system of AHE

AD83.70-W-6000-54C

24

Control unit output fuse carrier, testing electrical system of AHE

AD83.70-W-6000-41B

25

Control unit output auxiliary heater switch, testing electrical system of AHE

AD83.70-W-6000-72A

26

Auxiliary heater control unit, testing electrical system of AHE

AD83.70-W-6000-35C

27

Short-circuit in control unit, testing electrical system of AHE

AD83.70-W-6000-28A

28

Control unit output glow pin, testing electrical system of AHE

AD83.70-W-6000-42C

29

Control unit output circulation pump, testing electrical system of AHE

AD83.70-W-6000-43C

Referenced documents