ad8370s2000b

Auxiliary heater (AHE) diagnosis previous knowledge

Type ad · topic 83.70 · version 0102 · 2003-06-16

Applies to: MODEL 638.0 /1 /2 as of 15.10.97 with CODE (H12) Hot-water auxilary heater B5W S or D5W S MODEL 638.0 /1 /2 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer B5W S or D5W S

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 638 (models 0**, 1**, 2**)

AD83.70-S-2000B

Auxiliary heater (AHE) diagnosis previous knowledge

8.9.97

MODEL 638.0 /1 /2 as of 15.10.97 with CODE (H12) Hot-water auxilary heater
B5W S or D5W S

MODEL 638.0 /1 /2 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer
B5W S or D5W S

Danger!

Risk of explosion due to fuel vapors, risk of poisoning from combustion gases and risk of injury from burning during or after heater operation

Do not put stationary heater or engine with heater booster into operation in confined spaces or in the vicinity of tank installations. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

Location and assignment of connectors and sockets

GF00.19-S-1100A

Location and assignment of ground points

GF00.19-S-2000A

Location and assignment of cable connectors

GF00.19-S-3100A

Auxiliary heater (AHE) location of components

For model 638 with engines 111.948, 111.978, 601.942, 601.970 and model 638.244 with engine 104.900 only

GF83.70-S-0003-03B

Auxiliary heater (AHE) function description contents index

For models 638.094/194/294 only

GF83.70-S-0998A

Electrical wiring diagrams

For model 638 with engines 111.948, 111.978, 601.942, 601.970 and model 638.244 with engine 104.900 only

PE83.70-S-2001C

Electrical wiring diagrams

For model 638 with engines 111.948, 111.978, 601.942, 601.970 and model 638.244 with engine 104.900 only

PE83.70-S-2001D

Electrical wiring diagrams

For models 638.094/194/294 only

PE83.70-S-2001E

When disconnecting battery radio frequency remote control and auxiliary heater operating unit (A7) must be re-coupled

Connection and use of test equipment

AD00.00-S-1000AZ

Connect Hand-Held Tester, read out fault memory

AD00.00-S-2000-03A

With a fault display, cables, fuses, connectors and connections must be checked for open-circuit, good contact and correct connection in accordance with the currently valid circuit diagram.

Auxiliary heater connector assignment

AD83.70-S-2000-01B

Auxiliary heater diagnostic tools

AD83.70-S-2000-02B

Gauge at opened auxiliary heater diagnostic connector

For model 638 with engines 111.948, 111.978, 601.942, 601.970 and model 638.244 with engine 104.900 only

AD83.70-S-2000-03B

Gauge at opened auxiliary heater diagnostic connector

For models 638.094/194/294

AD83.70-S-2000-03C

Auxiliary heater function notes

AD83.70-S-2000-04A

Auxiliary heater (AHE) resistance values

AD83.70-S-2000-07B

Referenced documents