AD83.65-D-5000A | Cooling system diagnosis, troubleshooting | 26.1.04 |
MODEL 903.662, 904.662 with CODE (ZA8) Refrigerator vehicle
MODEL 903.662, 904.662
with CODE (ZA8) Refrigerator vehicle
with CODE (ZQ1) Stationary refrigeration for refrigerator vehicle
Cooling system diagnosis, previous knowledge | |||
| Ignition: OFF | ||
Error with fault code | Display in operating unit | ||
Fault text | Possible cause/note | Remedy | |
Cooling system operating unit, temperature display flashing | Cargo not sufficiently pre-cooled | ||
Ambient temperature too high. | |||
Cooling system malfunctioning | Check wiring, connectors and voltage supply of all components | ||
Cooling system faulty | Replace cooling system | ||
Evaporator fan nonfunctional | Evaporator fan voltage supply interrupted | Check wiring and connectors | |
Evaporator fan motor faulty | Replace evaporator fan | ||
Condenser fan nonfunctional | Condenser fan voltage supply interrupted | Check wiring and connectors | |
Condenser fan motor faulty | Replace condenser fan | ||
Refrigerant compressor nonfunctional | V-belt slipping | Tension V-belt and replace if necessary | |
V-belt damaged or torn | Replace V-belt | ||
Compressor clutch actuation | Check wiring and connectors | ||
Refrigerant compressor motor faulty | check, replace if necessary | ||
Refrigerant compressor faulty | Replace cooling system | ||
Refrigerant compressor motor nonfunctional | Voltage supply interrupted | Check wires and electrical connections | |
Load relay faulty | Replace load relay | ||
Carbon brushes worn | Replace carbon brushes | ||
Motor faulty | Replace motor | ||
Cooling system operating unit nonfunctional | Cooling system, main fuse 100 A triggered Cooling in driving mode | Check main fuse, replace if necessary | |
Stationary refrigeration, main fuse 100 A triggered with stationary refrigeration code ZQ1 | Check main fuse, replace if necessary | ||
Refrigeration voltage supply interrupted | Check voltage supply wiring and connections | ||
Connection to cooling system control unit interrupted | Check wiring and connectors | ||
Operating unit faulty | Replace operating unit | ||
Cooling system control unit faulty | Replace control unit | ||
Automatic defroster nonfunctional | Start manual defrosting Starts defrosting | ||
Replace control unit | |||
Does not start defrosting | |||
Check wiring and connections | |||
Replace control unit | |||
Replace cooling system | |||
Battery voltage too low, cooling system cannot be switched on | Voltage supply to cooling system control unit interrupted Battery voltage 10.7 V | Check wiring and connectors Check battery (or batteries), charge | |
Cooling system undervoltage protection in cooling system control unit faulty | Replace control unit | ||
Battery (or batteries) defective | Check battery (or batteries) and replace if necessary | ||
Load compartment doors difficult to close | Voltage supply to control electronics of load compartment venting actuator motor interrupted Overpressure builds up in load compartment when doors are closed | Check wiring and connectors | |
Voltage supply from control electronics to load compartment venting actuator motor interrupted | Replace control electronics Change actuator motor relay | ||
Load compartment venting actuator motor faulty | Replace actuator motor | ||
Stationary refrigeration not working, refrigeration in driving mode OK | 230 V voltage supply not present at stationary refrigeration power pack with stationary refrigeration code ZQ1 | Check connection to mains power supply Check position of stationary refrigeration switch | |
Fuse has triggered | Check mains fuse Check 230 V/16 A circuit breaker of stationary refrigeration Check power supply circuit breaker of stationary refrigeration Check 100 A fuse of stationary refrigeration | ||
Check wiring and connections of stationary refrigeration | Check wiring and connections | ||
Stationary refrigeration relay defective | Check relay, replace if necessary | ||
stationary refrigeration power pack faulty | Replace power pack | ||
Stationary refrigeration power supply unit fuse | Stationary refrigeration power supply unit fuse has triggered with stationary refrigeration code ZQ1 | Check fuse Check cool air supply to power supply unit | |
Power supply defective | Replace power supply unit | ||
Condensation dripping from evaporator paneling into load compartment | Condensation drain clogged | Blow through condensation hoses from inside to outside with compressed air | |