ad8340p3000d

Automatic air conditioning (Auto A/C) diagnosis operational check

Type ad · topic 83.40 · version 0100 · 2003-06-13

Applies to: MODEL 129 as of 1.6.96 with CODE (581a) Automatic air conditioning

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 129

AD83.40-P-3000D

Automatic air conditioning (Auto A/C) diagnosis operational check

25.2.98

MODEL 129 as of 1.6.96 with CODE (581a) Automatic air conditioning

Automatic air conditioning (AAC) diagnosis, function check

AD83.40-P-2000D

Prerequisites for function check, automatic air conditioning (AAC)

AD83.40-P-2000-01B

Function check

Test step

Operation/requirement

Specified value

Remedy

1

Defrosting

Function button

Any preselected temperature

Blower runs at higher speed.

Air flow from defroster air outlets.

AC compressor on, maximum heat output, 100% fresh air.

Testing electrical system:

AD83.40-P-6000-09D

AD83.40-P-6000-11D

AD83.40-P-6000-15D

AD83.40-P-6000-29A

AD83.40-P-6000-17D

AD83.40-P-6000-18D

AD83.40-P-6000-19K

2

Complete ventilation in cooling mode

Function button

Preselected temperature ""

Blower runs at higher speed.

Air flow at center and side air outlets.

AC compressor on, no heat output.

Testing electrical system:

AD83.40-P-6000-09D

AD83.40-P-6000-28A

AD83.40-P-6000-29A

AD83.40-P-6000-17D

AD83.40-P-6000-18D

AD83.40-P-6000-19K

Testing pneumatics:

AD83.40-P-8001-03B

3

Normal setting in control mode

Function button

Adjust preselected temperature corresponding to the interior temperature

Blower speed reduces.

Air flow at defroster air outlets, leak air from footwell outlets. AC compressor on. Temperature-controlled air flow. Mono valve cycles and the coolant circulation pump runs.

Testing electrical system:

AD83.40-P-6000-15D

AD83.40-P-6000-29A

AD83.40-P-6000-17D

AD83.40-P-6000-18D

AD83.40-P-6000-19K

Testing pneumatics:

AD83.40-P-8001-01B

AD83.40-P-8001-04B

4

Economy without heating mode

Preselected temperature ""

Function button

Function button

Air from center level (ambient air).

AC compressor off.

Testing electrical system:

AD83.40-P-6000-29A

AD83.40-P-6000-17D

AD83.40-P-6000-18D

Testing pneumatics:

AD83.40-P-8001-05B

5

Economy in heating mode

Preselected temperature ""

Function button

Air flow from footwell air outlets, left/right side air outlets.

Leak air from defroster air outlets.

Maximum heat output.

Testing electrical system:

AD83.40-P-6000-14D

AD83.40-P-6000-15D

AD83.40-P-6000-29A

AD83.40-P-6000-17D

AD83.40-P-6000-18D

AD83.40-P-6000-19K

Testing pneumatics:

AD83.40-P-8001-01B

6

Residual heat storage system

Ignition: OFF

Function button

Preselected temperature > 26 °C

Heated air from footwell air outlets, side air outlets, leak air from defroster air outlets. Blower runs at lower speed.

Testing electrical system:

AD83.40-P-6000-14D

AD83.40-P-6000-15D

AD83.40-P-6000-18D

AD83.40-P-6000-19K

Testing pneumatics:

AD83.40-P-8001-01B

Referenced documents