ad8340p3000c

Air conditioning (Automatic) (Automatic) A/C diagnosis, function check

Type ad · topic 83.40 · version 0103 · 2003-06-13

Applies to: MODEL 202 as of 1.9.95 with CODE (581a) Air conditioning (Automatic)

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 202

AD83.40-P-3000C

Air conditioning (Automatic) (Automatic) A/C diagnosis, function check

24.2.97

MODEL 202 as of 1.9.95 with CODE (581a) Air conditioning (Automatic)

Air conditioning (Automatic) (Automatic) A/C diagnosis, advanced information

AD83.40-P-2000C

a

Fuses F1/4, F1/7, F1/8

b

Aspirator blower for temperature sensor diagnosis, advanced information (Automatic) A/C

AD83.40-P-2000-17A

c

Allow engine to idle at operating temperature (approx. 80°C engine coolant temperature) during the complete duration of the test.

d

Open center and side outlets manually.

e

Recirculated air button not pressed.

Function check

Scope of test

Operation/Requirement

Specified value

Possible cause/Remedy

Defrosting

Function button

Any preselected temperature

Blower runs at increased speed.

Air flow at defroster outlets.

A/C compressor on, maximum heat output,

100% fresh air.

AD83.40-P-6000-09C

AD83.40-P-6000-11C

AD83.40-P-6000-15C

AD83.40-P-6000-16C

AD83.40-P-6000-19I

Complete ventilation in cooling mode

Function button

Preselected temperature "LO"

Blower runs at increased speed.

Air flow at center and side outlets.

A/C compressor on, no heat output.

AD83.40-P-6000-09C

AD83.40-P-6000-15C

AD83.40-P-6000-19I

AD83.40-P-6000-19B

AD83.40-P-6000-19C

AD83.40-P-6000-19D

AD83.40-P-6000-19E

AD83.40-P-6000-19F

AD83.40-P-6000-19G

AD83.40-P-8001-03A

Normal setting in control mode

Function button

Set preselected temperature corresponding to interior temperature

Blower speed reduces.

Airflow at defroster outlets and leak air from footwell outlets. A/C compressor on. Temperature-controlled air flow. Duovalve cycles and coolant circulation pump runs.

AD83.40-P-6000-10C

AD83.40-P-6000-15C

AD83.40-P-6000-19I

AD83.40-P-6000-19B

AD83.40-P-6000-19C

AD83.40-P-6000-19D

AD83.40-P-6000-19E

AD83.40-P-6000-19F

AD83.40-P-6000-19G

AD83.40-P-8001-01A

AD83.40-P-8001-04A

Economy without heating mode

Preselected temperature "LO"

Function button

Function button

Air from center level (ambient air).

A/C compressor off.

AD83.40-P-6000-17C

AD83.40-P-6000-19B

AD83.40-P-8001-05A

Economy in heating mode

Preselected temperature "HI"

Function button

Air flow from footwell outlets, left/right side outlets.

Leak air from defroster outlets.

Maximum heat output.

AD83.40-P-6000-15C

AD83.40-P-6000-16C

AD83.40-P-6000-18C

AD83.40-P-6000-19I

AD83.40-P-6000-19B

AD83.40-P-6000-19C

AD83.40-P-6000-19D

AD83.40-P-6000-19E

AD83.40-P-6000-19F

AD83.40-P-6000-19G

AD83.40-P-8001-01A

Residual heat storage system

Ignition: OFF

Function button

Preselected temperature > 26°C

Heated air from footwell outlets, side outlets, leak air from defroster outlets.

Blower runs at lower speed.

AD83.40-P-6000-15C

AD83.40-P-6000-16C

AD83.40-P-6000-17C

AD83.40-P-6000-18C

AD83.40-P-6000-19I

AD83.40-P-6000-19D

AD83.40-P-6000-19E

AD83.40-P-6000-19F

AD83.40-P-8001-01A

Referenced documents