ad8340p3000a

Air conditioning (Automatic) (Automatic) A/C diagnosis, function check

Type ad · topic 83.40 · version 0102 · 2003-06-13

Applies to: MODEL 208

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 208

AD83.40-P-3000A

Air conditioning (Automatic) (Automatic) A/C diagnosis, function check

11.2.97

MODEL 208

Air conditioning (Automatic) (Auto A/C) diagnosis, previous knowledge

AD83.40-P-2000A

Function check

Test step/Scope of test

Operation/Requirement

Specified value

Possible cause/Remedy

1

Defrosting

Function button

Any preselected temperature

Blower runs at increased speed.

Air flow from defroster outlets

A/C compressor on, maximum heat output, 100% fresh air.

AD83.40-P-6000-01A

AD83.40-P-6000-02A

AD83.40-P-6000-03A

AD83.40-P-6000-06A

AD83.40-P-6000-08A

AD83.40-P-6000-10A

AD83.40-P-6000-14A

AD83.40-P-6000-15A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

2

Complete ventilation in cool mode

Function button

Preselected temperature ""

Soft top completely closed (on model 208.4 only)

Blower runs at increased speed.

Air flow at center and side outlets.

A/C compressor on, no heat output.

Coolant circulation pump (M13) does not operate.

AD83.40-P-6000-04A

AD83.40-P-6000-05A

AD83.40-P-6000-06A

AD83.40-P-6000-08A

AD83.40-P-6000-14A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

AD83.40-P-8000-01A

AD83.40-P-8000-02A

3

Normal setting in control mode

Function button

Adjust preselected temperature corresponding to the interior temperature

Blower speed reduces.

Air flow at defroster outlets, leak air from footwell outlets. A/C compressor on. Temperature-controlled air flow. Duovalve cycles and the coolant circulation pump (M13) runs.

AD83.40-P-6000-09A

AD83.40-P-6000-10A

AD83.40-P-6000-11A

AD83.40-P-6000-13A

AD83.40-P-6000-14A

AD83.40-P-6000-15A

AD83.40-P-6000-16A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

AD83.40-P-8000-01A

AD83.40-P-8000-02A

4

Economy without heating mode

Preselected temperature ""

Function button

Function button

Air from center level (ambient air).

A/C compressor off.

AD83.40-P-6000-13A

AD83.40-P-6000-16A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

AD83.40-P-8000-01A

AD83.40-P-8000-02A

5

Economy with heating mode

Preselected temperature ""

Function button

Air flow from footwell outlets, left/right side outlets.

Leak air from defroster outlets.

Maximum heat output.

Coolant circulation pump (M13) runs.

AD83.40-P-6000-13A

AD83.40-P-6000-14A

AD83.40-P-6000-15A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

AD83.40-P-8000-01A

AD83.40-P-8000-02A

6

Recirculated air

Function button

Function button illuminated

AD83.40-P-8000-01A

AD83.40-P-8000-02A

7

Residual heat storage system

Ignition: OFF

Function button

Preselected temperature > °C

Heated air from footwell outlets, side outlets, leak air from defroster outlets. Blower runs at lower speed.

Coolant circulation pump (M13) runs.

AD83.40-P-6000-13A

AD83.40-P-6000-14A

AD83.40-P-6000-15A

AD83.40-P-6000-16A

AD83.40-P-6000-17A

AD83.40-P-6000-18A

AD83.40-P-6000-19A

AD83.40-P-8000-01A

AD83.40-P-8000-02A

Referenced documents