ad8330p3000b

Air conditioning (Tempmatic) diagnosis operational check

Type ad · topic 83.30 · version 0101 · 2003-06-13

Applies to: MODEL 202 as of 1.9.95, 208, 210 with CODE (580) Air conditioning or, for USA, Tempmatic

Where it sits

Function group 3 Body › 83 Climate control › 83.30 Air conditioning — Series 202 · Series 208 · Series 210

AD83.30-P-3000B

Air conditioning (Tempmatic) diagnosis operational check

19.2.98

MODEL 202 as of 1.9.95,
208, 210 with CODE (580) Air conditioning or, for USA, Tempmatic

Air conditioning (Tempmatic) (TAC) diagnosis, previous knowledge

AD83.30-P-2000B

Prerequisites for function check, air conditioning (Tempmatic) (TAC)

AD83.30-P-2000-01B

Function check

Test step/Scope of test

Operation/Requirement

Specified value

Possible cause/Remedy

1

Air drying

Temperature selectors on "white zone"

Function button not illuminated

Air distribution switch at 12 o'clock

Air from center level.

Air upwards.

A/C compressor ON.

Test electrical system:

AD83.30-P-6000B

Test pneumatics:

AD83.30-P-8000-02A

AD83.30-P-8000-03A

AD83.30-P-8000-04A

2

Normal setting in control mode

Temperature selectors on "white zone"

Function button not illuminated

Air distribution switch at 4 o'clock

Air upwards and downwards

A/C compressor ON.

Flow of temperature-controlled air from center level as well. The duo valve cycles and coolant circulation pump runs at the same time.

Test electrical system:

AD83.30-P-6000-08B

AD83.30-P-6000-20B

AD83.30-P-6000-16C

AD83.30-P-6000-16D

AD83.30-P-6000-17B

AD83.30-P-6000-18B

AD83.30-P-6000-19C

3

Economy without heating mode

Temperature selector engaged on "blue"

Function button illuminated

Air distribution switch at 9 o'clock

Air from center level (ambient air)

A/C compressor OFF.

Test electrical system:

AD83.30-P-6000-08B

AD83.30-P-6000-16C

AD83.30-P-6000-16D

4

Economy in heating mode

Temperature selector engaged on "red"

Function button illuminated

Air distribution switch at 4 o'clock

Heated air upwards, downwards and from center level.

A/C compressor OFF.

Test electrical system:

AD83.30-P-6000-08B

AD83.30-P-6000-16C

AD83.30-P-6000-16D

5

Residual heat storage system

Ignition: OFF

Function button

Temperature selectors on "red zone"

Air distribution switch at 4 o'clock

Heated air upwards, downwards and from center level.

Test electrical system:

AD83.30-P-6000-20B

AD83.30-P-6000-16C

AD83.30-P-6000-16D

6

Refrigerating capacity

Refrigerating capacity, function check, TAC

AD83.30-P-3000-01A

7

Control quality and heat output

Control quality and heat output

Function check, TAC

AD83.30-P-3000-02A

Diagnostic tools, air conditioning (Tempmatic) (TAC)

AD83.30-P-2000-04D

Referenced documents