ad8050d600041b

Lock switch, testing electrical system, anti-theft alarm (ATA)

Type ad · topic 80.50 · version 0100 · 2003-06-13

Applies to: MODEL 901, 902, 903, 904 with CODE (J67) Einbruch- / Diebstahlwarnanlage

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 901 · Series 902 · Series 903 · Series 904

EinPAS 29 Drive authorization/security system › 29.20 Anti-theft alarm system › 29.20.1 Basic information — Series 901 · Series 902 · Series 903 · Series 904

AD80.50-D-6000-41B

Lock switch, testing electrical system, anti-theft alarm (ATA)

Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Lock switch

(deactivate)

Ignition: ON

Istwert 06

No

Cable

Lock switch

1.1

1

S45

3

Ignition: OFF

Lock switch not operated

Lock switch operated

>20 kΩ

< 5Ω

Lock switch