ad8050d600028a

Anti-theft alarm (ATA) test of electrical system control module

Type ad · topic 80.50 · version 0100 · 2003-06-13

Applies to: MODEL 901, 902, 903, 904 with CODE (J67) Einbruch- / Diebstahlwarnanlage

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 901 · Series 902 · Series 903 · Series 904

EinPAS 29 Drive authorization/security system › 29.20 Anti-theft alarm system › 29.20.1 Basic information — Series 901 · Series 902 · Series 903 · Series 904

AD80.50-D-6000-28A

Anti-theft alarm (ATA) test of electrical system control module

Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

ATA control module

Seat box ground point

A18

13

Ignition: OF

Connector to ATA control module disconnected

<5 Ω

Cable

Seat box ground point

1.1

Voltage term. 30

13

A18

16

Ignition: OFF

Connector to ATA control module disconnected

11–14V

Fuse F85

Cable

1.2

Voltage term. 15

13

A18

10

Ignition: OFF

Connector to ATA control module disconnected

Ignition: ON

Ignition: OFF

11–14V

< 1V

Fuse F86

Cable