AD80.20-P-8000-07BB | Central locking, fuel tank flap, testing pneumatics, PSE | Pressure supply |
| Scope of test | Measuring instrument/ | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Central locking of fuel tank flap (pressure supply) Note on test connection: Fuel tank flap connection or fuel tank on PSE yellow connection on tester | Seal remaining pneumatic connections on PSE with rubber caps Close doors Vehicle locked via remote control Unlock vehicle via interior switch (CL) | 450 mbar in 0.8 s |
PSE (A37) | |||
Referenced documents
- ad8020p600101ba Interior switch (CL), testing electrical system, CL