ad8020d600136a

CL test of electrical system right sliding door rotary tumbler switch

Type ad · topic 80.20 · version 0101 · 2003-06-12

Applies to: MODEL 901, 902, 903, 904 with CODE (FZ0) Zentralverriegelung mit Hauptschlüssel '

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.20 Central locking system, interior central locking — Series 901 · Series 902 · Series 903 · Series 904

EinPAS 29 Drive authorization/security system › 29.16 Locking/unlocking › 29.16.1 Basic information — Series 901 · Series 902 · Series 903 · Series 904

AD80.20-D-6001-36A

CL test of electrical system right sliding door rotary tumbler switch

Scope of test

Tester/test connection

Operation/

Requirement

Specified value

Possible cause/

Remedy

1.0

Operation of rotary tumbler switch

Right sliding door

A

4/1

D

1/1

Open right sliding door

Move tumbler at door lock by hand into "Sliding door closed" position

measured at contact plate (pin) X27

GF80.20-D-0005-02C

> 5 Ω

5 Ω

Wiring to door

Wiring to control module

Rotary tumbler switch

Referenced documents