AD80.20-D-6001-36A | CL test of electrical system right sliding door rotary tumbler switch |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Operation of rotary tumbler switch Right sliding door | A 4/1 |
| D 1/1 | Open right sliding door Move tumbler at door lock by hand into "Sliding door closed" position measured at contact plate (pin) X27 | > 5 Ω 5 Ω | Wiring to door Wiring to control module Rotary tumbler switch |
Referenced documents
- gf8020d000502c Central locking (CL), location of electric components