AD72.40-W-6000A | Folding door test, electrical system | 9.10.09 |
MODEL 957.### #Z up to 930156 with BODY 957.810
with folding door, Ikarus
Modification notes
Danger! | Risk of injury from pinching and crushing when working on the folding door and the folding door control system | When working on the folding door or folding door control, relieve pressure from system with emergency lever (off position). | |
| Battery voltage min. 22.5 V, operating pressure and fuses okay | ||
Folding door diagnosis, previous knowledge | |||
Checking | |||
1 | Pressure wave switch test, electrical system, folding door | Pressure wave switch (S128) | |
2 | Door lock switch test, electrical system, folding door | Door lock switch (S126) | |
3 | Exterior pushbutton test, electrical system, folding door | Passenger side outside door open/close button (S117) | |
4 | Interior pushbutton test, electric system, folding door | Door open/close button (S118) | |
5 | Door open/close button limit switch test, electrical system, folding door | Door open/closed limit switch (S129) | |
6 | Closing door test, electrical system, folding door | Test with door open/close button (S118) | |
7 | Closing door test, electrical system, folding door | Test with passenger side outside door open/close button (S129) | |
8 | Opening door test, electrical system, folding door | Test with door open/close button (S118) | |
9 | Opening door test, electrical system, folding door | test with passenger side outside door open/close button (S129) | |
10 | Automatic closing test, electrical system, folding door | ||
11 | Pressure-dependent powerless control test, electrical system, folding door |
Referenced documents
- ad7240w2000a Folding door diagnosis, previous knowledge
- ad7240w600002a Pressure wave switch test, electrical system, folding door
- ad7240w600003a Door lock switch test, electrical system, folding door
- ad7240w600004a Exterior pushbutton test, electrical system, folding door
- ad7240w600005a Interior pushbutton test, electric system, folding door
- ad7240w600006a Limit switch test, electrical system, folding door
- ad7240w600007a Closing door test, electrical system, folding door
- ad7240w600007b Closing door test, electrical system, folding door
- ad7240w600008a Opening door test, electrical system, folding door
- ad7240w600008b Opening door test, electrical system, folding door
- ad7240w600009a Automatic closing test, electrical system, folding door
- ad7240w600012a Pressure-dependent powerless control test, electrical system, folding door
- as7200z000101a Injury hazard! When working on folding door or folding door control body parts can be pinched or crushed