Danger!

Risk of injury from pinching and crushing when working on the folding door and the folding door control system

When working on the folding door or folding door control, relieve pressure from system with emergency lever (off position).

AS72.00-Z-0001-01A

Battery voltage min. 22.5 V, operating pressure and fuses okay

Folding door diagnosis, previous knowledge

AD72.40-W-2000A

Folding door, location of components

GF72.15-W-0001-01B

Troubleshooting

Complaint

Possible cause

Note

Remedy

Folding door nonfunctional

No compressed air supply

Compressed air line to compressed air supply on folding door control kinked

AR72.40-W-1045A

Door open/close button on outer passenger side nonfunctional

Door open/close button on outer passenger side defective

AD72.40-W-6000-04A

Door open/close button nonfunctional

Door open/close button defective

AD72.40-W-6000-05A

Folding door does not close

Door open/closed limit switch incorrectly adjusted

AR72.40-W-1000-03A

Door open/closed limit switch defective

AD72.40-W-6000-06A

Automatic closing does not operate

No vehicle speed signal present

AD72.40-W-6000-09B

Reversing system does not operate

Door open/closed limit switch incorrectly adjusted

AR72.40-W-1000-03A

Door open/closed limit switch defective

AD72.40-W-6000-06A

Pressure wave hose defective

Pressure wave switch faulty

AD72.40-W-6000-02A