AD46.80-B-3002B | Additional steered axle (ZL) diagnosis, function check by means of actuation | 12.02.16 |
Vehicle 382.15, 634.0 with Rear axle 749.282 with CODE AN9 (Hydraulically steered trailing axle)
B46.80-0003-01
Driven back axle centering switch
B46.80-0004-08
1 Hydraulic cylinder
X Distances between centering cylinder faces and round end piece
| Measure | ||
1 | Position the vehicle in front and in straight line | Before lining up the hydraulic cylinder, ensure that: for vehicles O500 RS/RSD, with driven back axle, the front axle wheels are aligned; or, for articulated O500 vehicles, with driven back axle, the cars are aligned. | |
2 | Lift the driven back axle and put it over the rotating table | Rotating table. | |
3 | Line up the hydraulic cylinder mechanically | Steer the driven back axle until the "X" measure is the same on both sides, that is, the hydraulic cylinder will be centered mechanically when symmetry is reached between the sides. | |
Actuation | |||
4 | Connect Star Diagnosis | ||
5 | Start ignition | ||
6 | Access "Xentry" | Select "Continue" | |
7 | Identify vehicle through VIN | ||
8 | Select "XENTRY Diagnostics" | ||
9 | On DAS, perform quick test. | ||
10 | Access "Auxiliary steering ZL" control mechanism drive module | Select Continue "F3" | |
11 | Safety instructions | Actuation with the vehicle parked and parking brake applied, gearbox in neutral, parameterized system, engine working and centered driven back axle are mandatory . Select Continue "F2". | |
12 | Select "Control mechanism drive adaptation" | Select Continue "F3" | |
13 | Select "Parameterization" | Select Continue "F3". | |
14 | Select "Individual Parameterization" | Select Continue "F3". | |
15 | Select "Calibration value register" | Select Continue "F3" . | |
16 | Driven back axle calibration | The measured power sensor current value from the directional axle must be within specification. | |
| Check | ||
17 | Verify the centering cylinder basic position | Use driven back axle centering switch on the panel . | |
| Verify, adjust the centering cylinder basic position |
Referenced documents
- ar4680b000201a Check/adjust basic setting of centering cylinder