AD32.33-S-6000A | Electronic level adjustment (ELA), electrical system testing | 28.8.97 |
MODEL 638 with CODE (CL0), Raise/lower rear pneumatic suspension
Connection and use of test equipment | |||
Electronic level adjustment (ELA) diagnosis previous knowledge | |||
| Only disconnect control module connectors with ignition switched off | ||
| Cables, plugs and connections are taken into consideration when testing using the HHT. If a fault is displayed, they may have to be tested separately for an open circuit, good contact and proper connection as per the respective valid wiring diagram. Static testing is often inadequate because lead vibration, engine at idling speed etc. can only be tested dynamically. | ||
| Electric wiring diagrams | ||
| Electronic level adjustment (ELA) component arrangement | ||
a | Battery voltage 11-14 volts | All consumers switched on with engine running and charge monitoring lamp off. | |
b | Complete ELA system (all connectors connected) | ||
c | HHT connected to diagnosis socket | ||
d | In order to protect the vehicle battery, service mode should be activated when working on the pneumatic suspension. | ||
Testing | |||
1 | ELA electrical system testing, ELA control module | ||
2 | ELA electrical system testing, starter operation signal | ||
3 | ELA electrical system testing, D+ signal | ||
4 | ELA electrical system testing, stop lamp signal | ||
5 | ELA electrical system testing, service mode | ||
6 | ELA electrical system testing, door contact signal | ||
7 | ELA electrical system testing, raise/lower pneumatic spring switch | ||
8 | ELA electrical system testing, ELA warning lamp | ||
9 | ELA electrical system testing, speed signal | ||
10 | ELA electrical system testing, barometric pressure sensor | ||
11 | ELA electrical system testing, right transverse shutoff valve | ||
12 | ELA electrical system testing, left transverse shutoff valve | ||
13 | ELA electrical system testing, outlet valve | ||
14 | ELA electrical system testing, compressor relay | ||
15 | ELA electrical system testing, compressor |
Referenced documents
- ad0000s1000az Connection and use of testing equipment
- ad3233s2001a Diagnosis previous knowledge, electronic level adjustment (ELA)
- ad3233s600001a ELA electrical system testing, ELA control module
- ad3233s600002a ELA electrical system testing, starter operation signal
- ad3233s600003a ELA electrical system testing, D+ signal
- ad3233s600004a ELA electrical system testing, stop lamp signal
- ad3233s600005a ELA electrical system testing, service mode
- ad3233s600006a ELA electrical system testing, door contact signal
- ad3233s600009a ELA electrical system testing, ELA warning lamp
- ad3233s600010a ELA electrical system testing, speed signal
- ad3233s600011a ELA electrical system testing, barometric pressure sensor
- ad3233s600012a ELA electrical system testing, right transverse shutoff valve
- ad3233s600013a ELA electrical system testing, left transverse shutoff valve
- ad3233s600014a ELA electrical system testing, outlet valve
- ad3233s600015a ELA electrical system testing, compressor relay
- ad3233s600016a ELA electrical system testing, compressor
- ad3233s600017a ELA electrical system testing, pneumatic spring raise/lower switch
- gf3233s000102a Electronic level control - (ENR/NR) arrangement of components
- pe3200s1100a Survey of electric circuit wiring diagrams suspension