AD32.33-L-6000-28C | ENR test of electrical system front solenoid valve | With fault code |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | FA solenoid valve – Short-circuit between pin 10 and 14/18/ground With fault code 133 | Ignition: On Disconnect connector on front axle ENR solenoid valve (Y11) | Fault code Fault code | Replace front axle ENR solenoid valve (Y11) Carry out visual inspection on wiring harness and connectors. If no fault can be found 1.1 | |||
1.1 | FA solenoid valve – Short-circuit between pin 10 and 14/18/ground |
1 |
Y11 | X37 1 2 | Ignition: Off Disconnect connector X37 | Actual value towards Actual valve approx. 0 Ω |
Short-circuit between green/white/yellow cable and ground or cable short-circuit to a ground cable on wiring harness from ENR control unit (A6) to connector X37 Short-circuit between green/white/yellow cable and ground or cable short-circuit to a ground cable (wiring harness from connector X37 to front axle ENR solenoid valve (Y11)) |