Series
en
ad3036w600207c
GBL test of electrical system linear adjuster
Type ad · topic 30.36 · version 0100 · 2003-06-10
Applies to: ENGINE 441.9, 445.9, 446.9 in MODEL 625.1 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 446.9 in MODEL 625.2 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 441.9, 445.9 in MODEL 650, 651, 652, 653, 654 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 401.9 in MODEL 653, 654 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 402.9, 440.9, 442.9, 445.9, 446.9 in MODEL 655 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h E
Where it sits
Function group 1 Engine › 30 Throttle control, speed control systems › 30.36 Speed limiter (GB, GBE, GBL) — Series 440 (models 9**) · Series 441 (models 9**) · Series 442 (models 9**) · Series 625 (models 1**, 2**) · Series 650 · Series 651 · Series 652 · Series 653 · Series 654 · Series 655 · Series 656 · Series 657 · Series 658 · Series 659
EinPAS 28 Convenience system/driver assistance system › 28.25 Speed control › 28.25.1 Basic information — Series 440 (models 9**) · Series 441 (models 9**) · Series 442 (models 9**) · Series 625 (models 1**, 2**) · Series 650 · Series 651 · Series 652 · Series 653 · Series 654 · Series 655 · Series 656 · Series 657 · Series 658 · Series 659
Also applies to engines/gearboxes: 401 9**, 402 9**, 445 9**, 446 9**
AD30.36-W-6002-07C
GBL test of electrical system linear adjuster
Scope of test
Measuring instrument/
Test connection
Operation/Requirement
Specified value
Possible cause/Remedy
1.0
Linear actuator
Carry out on vehicles with fault code read out only.
6
(II-6/2)
8
(II-6/4)
Bring engine to working temperature (by mechanical means).
Ignition: OFF
Contact test cable set no. 655 589 01 63 00 and socket box
AD30.36-W-2002-02A
< 80 Ω
Linear actuator
Supply line to linear actuator
Plug connection(s) oxidized
1.1
Linear actuator
6
(II-6/2)
9
(II-6/5)
Ignition: OFF
approx. 0.9 kΩ
Value approx. 1.8 kΩ:
End switch S1 or S2 open
Value > 2 kΩ:
End switch S1 and S2 open
Supply line to linear actuator
1.2
Linear actuator
8
(II-6/4)
9
(II-6/5)
Ignition: OFF
approx. 0.9 kΩ
Value approx. 1.8 kΩ:
End switch S1 or S2 open
Value > 2 kΩ:
End switch S1 and S2 open
Supply line to linear actuator
Referenced documents