ad3036w600207c

GBL test of electrical system linear adjuster

Type ad · topic 30.36 · version 0100 · 2003-06-10

Applies to: ENGINE 441.9, 445.9, 446.9 in MODEL 625.1 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 446.9 in MODEL 625.2 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 441.9, 445.9 in MODEL 650, 651, 652, 653, 654 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 401.9 in MODEL 653, 654 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h ENGINE 402.9, 440.9, 442.9, 445.9, 446.9 in MODEL 655 with CODE (MA1) Linear vehicle speed limiter (GBL) 80 km/h E

Where it sits

Function group 1 Engine › 30 Throttle control, speed control systems › 30.36 Speed limiter (GB, GBE, GBL) — Series 440 (models 9**) · Series 441 (models 9**) · Series 442 (models 9**) · Series 625 (models 1**, 2**) · Series 650 · Series 651 · Series 652 · Series 653 · Series 654 · Series 655 · Series 656 · Series 657 · Series 658 · Series 659

EinPAS 28 Convenience system/driver assistance system › 28.25 Speed control › 28.25.1 Basic information — Series 440 (models 9**) · Series 441 (models 9**) · Series 442 (models 9**) · Series 625 (models 1**, 2**) · Series 650 · Series 651 · Series 652 · Series 653 · Series 654 · Series 655 · Series 656 · Series 657 · Series 658 · Series 659

Also applies to engines/gearboxes: 401 9**, 402 9**, 445 9**, 446 9**

AD30.36-W-6002-07C

GBL test of electrical system linear adjuster

Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Linear actuator

Carry out on vehicles with fault code read out only.

6

(II-6/2)

8

(II-6/4)

Bring engine to working temperature (by mechanical means).

Ignition: OFF

Contact test cable set no. 655 589 01 63 00 and socket box

AD30.36-W-2002-02A

< 80 Ω

Linear actuator

Supply line to linear actuator

Plug connection(s) oxidized

1.1

Linear actuator

6

(II-6/2)

9

(II-6/5)

Ignition: OFF

approx.
0.9 kΩ

Value approx. 1.8 kΩ:

End switch S1 or S2 open

Value > 2 kΩ:

End switch S1 and S2 open

Supply line to linear actuator

1.2

Linear actuator

8

(II-6/4)

9

(II-6/5)

Ignition: OFF

approx.
0.9 kΩ

Value approx. 1.8 kΩ:

End switch S1 or S2 open

Value > 2 kΩ:

End switch S1 and S2 open

Supply line to linear actuator

Referenced documents