Transmission | 724.2 |
Transmission | 725.0 in model 167.117/154/317/354 |
Transmission | 725.0 in model 205 |
with code ME05 (Hybrid drive 85 kW-94 kW variant (incl. plug-in)) | |
Transmission | 725.0 in model 213.011/016/050/053/054/153/155/211/216/253 |
Transmission | 725.0 in model 222 |
with code ME05 (Hybrid drive 85 kW-94 kW variant (incl. plug-in)) | |
Transmission | 725.0 in model 253 |
with code ME05 (Hybrid drive 85 kW-94 kW variant (incl. plug-in)) |
Test procedure | Measuring instrument/test connection | Specified value | Enter result in test log? | |||
Exclusively use the following values on removed transmissions following transmission repair. | ||||||
Valid for electric machine of Generation 1 (Bosch): | ||||||
1 | Interlock in transmission | Digital multimeter, test box | Pin 9 | Pin 10 | Ω | Yes |
2 | Temperature sensor | Digital multimeter, test box | Pin 7 | Pin 8 | 11 3 kΩ | No |
3 | Excitation winding resolver resistor | Digital multimeter, test box | Pin 1 | Pin 2 | 19 4 Ω | No |
4 | Resolver resistor sin | Digital multimeter, test box | Pin 5 | Pin 6 | 90 10 Ω | No |
5 | Resolver resistor cos | Digital multimeter, test box | Pin 3 | Pin 4 | 100 15 Ω | No |
Valid for an electric machine of Generation 2 (SA code: A18 (rear axle HL2/54D-8.6)): | ||||||
1 | Interlock in transmission | Digital multimeter, test box | Pin 9 | Pin 10 | Ω | Yes |
2 | Temperature sensor | Digital multimeter, test box | Pin 7 | Pin 8 | 11 3 kΩ | No |
3 | Excitation winding resolver resistor | Digital multimeter, test box | Pin 1 | Pin 2 | 19 4 Ω | No |
4 | Resolver resistor sin | Digital multimeter, test box | Pin 5 | Pin 6 | 75 15 Ω | No |
5 | Resolver resistor cos | Digital multimeter, test box | Pin 3 | Pin 4 | 80 10 Ω | No |