AD00.19-N-9012EA | Fault code list for gear control (GS) control unit | 11.1.08 |
MODEL 374.5 /6, 375.3 /4, 940, 942, 943, 944
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.890
MODEL 958.2 /4
Fault code | Fault code description |
0160 | Vehicle CAN bus faulty |
0161 | Communication fault on vehicle CAN bus |
0162 | Communication fault with control unit FR drive control (FMR) |
0163 | Communication fault with control unit PSM Parameterizable Special Module |
0164 | Communication fault with control unit WSK torque converter-clutch |
0165 | Communication fault with control unit RS retarder control (RET) |
0166 | Communication fault with control unit ABS anti-lock braking system or BS brake control (EPB) |
0167 | Communication fault with control unit INS Instrument |
0168 | Communication fault with control unit KS clutch control (MKR) |
0169 | Communication fault with control unit AG automatic gear selection (AGE) |
0170 | Communication fault with control unit MR engine control (PLD) |
0173 | Transmission CAN databus in single-wire mode |
0175 | No signal from control unit INS or signal is faulty. |
1010 | Internal error in control unit GS II or Internal fault in control unit |
1011 | Learning data invalid |
1012 | Control unit GS II is incorrectly parameterized. or Control unit GS gear control (EPS) is incorrectly parameterized. |
1013 | Clutch position control fault |
1014 | Internal error in control unit GS II |
1080 | TEST electronics |
1082 | Test bench mode active |
1101 | Overvoltage at terminal 30 |
1102 | Undervoltage at terminal 30 |
1103 | Line of circuit 30A or of circuit 30B has Open circuit. |
1201 | Ground cable for control module has fault Open circuit. |
1301 | Overvoltage at terminal 15 |
1302 | Undervoltage at terminal 15 |
1403 | Internal error in control unit GS II |
1503 | Voltage supply for shift control unit has fault Open circuit. |
1504 | Voltage supply of rpm sensor B57/B99 has Short circuit to ground. or Voltage supply for shift control unit and rotary sensor B57 has fault Short circuit to ground. |
1505 | Voltage supply of rpm sensor B57/B99 has Short circuit to positive. or Voltage supply for shift control unit and rotary sensor B57 has fault Short circuit to positive. |
1803 | Internal error in control unit GS II |
2030 | Communication fault with shift control unit |
2031 | Ground cable for shift control unit has fault Open circuit. |
2032 | Cable for emergency shift has fault Open circuit. |
2033 | Cable for emergency shift has fault Short circuit to ground. |
2034 | Cable for emergency shift has fault Short circuit to positive. |
2035 | Enable fault emergency shift electronics |
2036 | Emergency shift has failed. |
2037 | Feedback output stage is faulty. |
3020 | Solenoid valve MS1 has Open circuit. or Valve block GS (EPS), solenoid valve MS1 has fault Open circuit. |
3021 | Solenoid valve MS2 has Open circuit. or Valve block GS (EPS), solenoid valve MS2 has fault Open circuit. |
3022 | Solenoid valve MS1 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MS1 has fault Short circuit to ground. |
3023 | Solenoid valve MS2 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MS2 has fault Short circuit to ground. |
3024 | Solenoid valve MS1 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MS1 has fault Short circuit to positive. |
3025 | Solenoid valve MS2 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MS2 has fault Short circuit to positive. |
3120 | Solenoid valve MUB has Open circuit. or Valve block GS (EPS), solenoid valve MUB has fault Open circuit. |
3121 | Solenoid valve MGB has Open circuit. or Valve block GS (EPS), solenoid valve MGB has fault Open circuit. |
3122 | Solenoid valve MUB has Short circuit to ground. or Valve block GS (EPS), solenoid valve MUB has fault Short circuit to ground. |
3123 | Solenoid valve MGB has Short circuit to ground. or Valve block GS (EPS), solenoid valve MGB has fault Short circuit to ground. |
3124 | Solenoid valve MUB has Short circuit to positive. or Valve block GS (EPS), solenoid valve MUB has fault Short circuit to positive. |
3125 | Solenoid valve MGB has Short circuit to positive. or Valve block GS (EPS), solenoid valve MGB has fault Short circuit to positive. |
3220 | Solenoid valve MUE has Open circuit. or Valve block GS (EPS), solenoid valve MUE has fault Open circuit. |
3221 | Solenoid valve MGE has Open circuit. or Valve block GS (EPS), solenoid valve MGE has fault Open circuit. |
3222 | Solenoid valve MUE has Short circuit to ground. or Valve block GS (EPS), solenoid valve MUE has fault Short circuit to ground. |
3223 | Solenoid valve MGE has Short circuit to ground. or Valve block GS (EPS), solenoid valve MGE has fault Short circuit to ground. |
3224 | Solenoid valve MUE has Short circuit to positive. or Valve block GS (EPS), solenoid valve MUE has fault Short circuit to positive. |
3225 | Solenoid valve MGE has Short circuit to positive. or Valve block GS (EPS), solenoid valve MGE has fault Short circuit to positive. |
3320 | Solenoid valve MG1 has Open circuit. or Valve block GS (EPS), solenoid valve MG1 has fault Open circuit. |
3321 | Solenoid valve MG2 has Open circuit. or Valve block GS (EPS), solenoid valve MG2 has fault Open circuit. |
3322 | Solenoid valve MG1 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MG1 has fault Short circuit to ground. |
3323 | Solenoid valve MG2 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MG2 has fault Short circuit to ground. |
3324 | Solenoid valve MG1 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MG1 has fault Short circuit to positive. |
3325 | Solenoid valve MG2 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MG2 has fault Short circuit to positive. |
3326 | Solenoid valve MG1 has Open circuit. |
3328 | Solenoid valve MG1 has Short circuit to ground. |
3420 | Solenoid valve MR1 has Open circuit. or Valve block GS (EPS), solenoid valve MR1 has fault Open circuit. |
3421 | Solenoid valve MR2 has Open circuit. or Valve block GS (EPS), solenoid valve MR2 has fault Open circuit. |
3422 | Solenoid valve MR1 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MR1 has fault Short circuit to ground. |
3423 | Solenoid valve MR2 has Short circuit to ground. or Valve block GS (EPS), solenoid valve MR2 has fault Short circuit to ground. |
3424 | Solenoid valve MR1 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MR1 has fault Short circuit to positive. |
3425 | Solenoid valve MR2 has Short circuit to positive. or Valve block GS (EPS), solenoid valve MR2 has fault Short circuit to positive. |
3520 | Solenoid valve MKUB1 has Open circuit. |
3521 | Solenoid valve MKUB2 has Open circuit. |
3522 | Solenoid valve MKUB1 has Short circuit to ground. |
3523 | Solenoid valve MKUB2 has Short circuit to ground. |
3524 | Solenoid valve MKUB1 has Short circuit to positive. |
3525 | Solenoid valve MKUB2 has Short circuit to positive. |
3620 | Solenoid valve MKUE1 has Open circuit. |
3621 | Solenoid valve MKUE2 has Open circuit. |
3622 | Solenoid valve MKUE1 has Short circuit to ground. |
3623 | Solenoid valve MKUE2 has Short circuit to ground. |
3624 | Solenoid valve MKUE1 has Short circuit to positive. |
3625 | Solenoid valve MKUE2 has Short circuit to positive. |
3703 | Common ground cable of solenoid valves MKUE1 and MKUB1 has Open circuit. |
3704 | Common ground cable of solenoid valves MKUE1 and MKUB1 has Short circuit to ground. |
3705 | Common ground cable of solenoid valves MKUE1 and MKUB1 has Short circuit to positive. |
3803 | Common ground cable of solenoid valves MR1, MR2, MUG and MGG has Open circuit. or Common ground cable of the solenoid valves has fault Open circuit. |
3804 | Common ground cable of solenoid valves MR1, MR2, MUG and MGG has Short circuit to ground. or Common ground cable of the solenoid valves has fault Short circuit to ground. |
3805 | Common ground cable of solenoid valves MR1, MR2, MUG and MGG has Short circuit to positive. or Common ground cable of the solenoid valves has fault Short circuit to positive. |
3903 | Common ground cable of solenoid valves MKUE2 and MKUB2 has Open circuit. |
3904 | Common ground cable of solenoid valves MKUE2 and MKUB2 has Short circuit to ground. |
3905 | Common ground cable of solenoid valves MKUE2 and MKUB2 has Short circuit to positive. |
4040 | Sensor 'Split' has Open circuit. or 'Splitter' sensor has fault Open circuit. |
4041 | Sensor 'Split' has Short circuit to ground. or 'Splitter' sensor has fault Short circuit to ground. |
4042 | Sensor 'Split' has Short circuit to positive. or 'Splitter' sensor has fault Short circuit to positive. |
4043 | Operational fault of component Splitter sensor |
4044 | Component Splitter sensor not within permissible range of values |
4140 | Sensor 'Gear' has Open circuit. or 'Gear' sensor has fault Open circuit. |
4141 | Sensor 'Gear' has Short circuit to ground. or 'Gear' sensor has fault Short circuit to ground. |
4142 | Sensor 'Gear' has Short circuit to positive. or 'Gear' sensor has fault Short circuit to positive. |
4143 | Operational fault of component Gear sensor |
4144 | Component Gear sensor not within permissible range of values |
4240 | Sensor 'Gate' has Open circuit. or 'Gate' sensor has fault Open circuit. |
4241 | Sensor 'Gate' has Short circuit to ground. or 'Gate' sensor has fault Short circuit to ground. |
4242 | Sensor 'Gate' has Short circuit to positive. or 'Gate' sensor has fault Short circuit to positive. |
4243 | Operational fault of component Gate sensor |
4244 | Component Gate sensor not within permissible range of values |
4340 | Sensor 'Range' has Open circuit. or 'Range' sensor has fault Open circuit. |
4341 | Sensor 'Range' has Short circuit to ground. or 'Range' sensor has fault Short circuit to ground. |
4342 | Sensor 'Range' has Short circuit to positive. or 'Range' sensor has fault Short circuit to positive. |
4343 | Operational fault of component Range sensor |
4344 | Component Range sensor not within permissible range of values |
4440 | Clutch travel sensor has Open circuit. or Clutch travel sensor has fault Open circuit. |
4441 | Clutch travel sensor has Short circuit to ground. or Clutch travel sensor has fault Short circuit to ground. |
4442 | Clutch travel sensor has Short circuit to positive. or Clutch travel sensor has fault Short circuit to positive. |
4443 | Operational fault of component Clutch travel sensor or Operational fault of component Clutch travel sensor |
4444 | Component Clutch travel sensor not within permissible range of values or Component Clutch travel sensor not within permissible range of values |
4540 | Oil temperature sensor has Short circuit to positive or Open circuit. |
4542 | Oil temperature sensor has Short circuit to ground. |
5040 | No signal from rpm sensor B57. or No signal from rotary sensor B57. |
5043 | Operational fault of component B57 |
5140 | No signal from rpm sensor B3 'Countershaft'. or No signal from rotary sensor B3. |
5141 | Speed sensor B3 for countershaft has fault Short circuit to ground. |
5142 | Rpm sensor B3 for countershaft has fault Open circuit or Short circuit to positive. |
5143 | Malfunction in rpm sensor B3 'Countershaft' or Operational fault of component Speed sensor for countershaft |
5145 | Rpm sensor B3 'Countershaft' has Open circuit or Short circuit to ground. |
5146 | Rpm sensor B3 'Countershaft' has Short circuit to positive. |
5240 | No signal from tachograph P1 or No C3 signal / speed pulse |
5243 | Signal from tachograph P1 interrupted or Fault in C3 signal / speed pulse |
5340 | No signal from rpm sensor B99. or No signal from rotary sensor B99. |
5343 | Operational fault of component B99 |
6003 | Solenoid valve 'Countershaft brake (VGW-B)' has Open circuit. |
6004 | Solenoid valve 'Countershaft brake (VGW-B)' has Short circuit to ground. |
6005 | Solenoid valve 'Countershaft brake (VGW-B)' has Short circuit to positive. |
7003 | Internal error in control unit GS II |
8091 | Not transmission output speed or No rpm |
8092 | Transfer case incorrect or not parameterized |
8093 | Incorrect transmission type |
8094 | Direction of travel determined is implausible. |
8095 | Clutch position: below minimum learned value |
8096 | Clutch position: above maximum learned value |
8097 | The number of teeth of the pulse wheel at the transmission output is implausible. |
8099 | The resistance value of the position sensor is implausible. |
8185 | Plausibility error of specified value 'Clutch position control' |
8186 | Plausibility error due to clutch opening |
8187 | Plausibility error due to clutch closing |