5 | Gas shut-off cock | 7 | Hinged door | 10 | Quick-release coupling | ||
6 | Sliding door | 8 | Shelf | 11 | Cover |
1 | Clamping wedge |
2 | Gas pressure regulator |
3 | Union nut |
4 | Shutoff valve |
N86.60-2033-12
Danger ! | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
| Notes on carrying out repair work in the vehicle interior | ||
| Remove/install | ||
1 | Close gas shut-off cock (5) | See owner's manual. | |
2 | Open sliding door (6) | ||
3 | Open hinged door (7) | ||
4 | Remove floor (8) from rotating cabinet | ||
5 | Release quick-release couplings (10) and remove cover (11) | ||
6 | Close shut-off valve (4) on gas cylinder | See owner's manual. | |
7 | Unscrew union nut (3) | Installation: | |
Observe left-hand thread on union nut (3). | |||
Installation: Check seal for union nut (3) for damage. | |||
If seal for union nut (3) is damaged | |||
| |||
Replace seal for union nut (3) | |||
8 | Lay gas pressure regular (2) down to side | Installation: Check seal on gas pressure regulator (2) for damage. | |
If seal on gas pressure regulator (2) is damaged | |||
| |||
Replace seal on gas pressure regulator (2) | |||
9 | Loosen clamping wedge (1) and lay down to side | Do not remove check strap on clamping wedge (1). | |
10 | Remove gas bottle | | |
The gas system is designed for an operating pressure of 30 mbar. | |||
11 | Install in the reverse order |