P05.10-2291-01
1 Bolts
G2 Alternator
P05.10-2309-12
3 Poly-V belt
5 Timing case cover
6 Chain tensioner
7 Sealing ring
G2 Alternator
| Remove/install | ||
Danger! | Risk of injury caused by fingers being pinched or crushed when removing, installing or aligning hoods, doors, trunk lids, tailgates or sliding roof. | Keep body parts and limbs well clear of moving parts. | |
1 | Open engine hood and raise to vertical position | ||
2 | Remove partition wall between wheelhouses | ||
Danger! | Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
3 | Disconnect ground line from battery | Insulate clamping device of the ground line in order to prevent inadvertent contact with the ground point of the battery. | |
| Notes on battery | All models | |
4 | Remove left and right suction fan duct | ||
5 | Remove front engine cover | ||
6 | Partially remove poly-V belt (3) | ||
7 | Remove bolts (1) and lay alternator (G2) to the side with attached lines | | |
External Torx set | |||
8 | Remove chain tensioner (6) from timing case cover (5) | Installation: Replace seal (7). | |
| |||
| Design of chain tensioner | ||
9 | Install in the reverse order | ||
10 | Read out fault memory and erase if necessary | STAR DIAGNOSIS diagnosis system | |
| Connect STAR DIAGNOSIS and read out fault memory |
Timing chain, chain tensioner
Number | Designation | Engine 113.940/941/ | ||
BA05.10-P-1002-01B | Chain tensioner housing in timing case cover | Nm | 80 | |
Alternator
Number | Designation | Engine | ||
BA15.40-P-1005-01N | Self-tapping screw, alternator to timing case | Thread not pre-tapped | Nm | 60 |
Thread pre-tapped | Nm | 45 | ||
001 589 76 09 00
External Torx set
Έγγραφα που αναφέρονται
- ad0000p200004a Σύνδεση Star Diagnosis, ανάγνωση μνήμης βλαβών
- ad0000p200004a
- ah5410p000101a Υποδείξεις για την μπαταρία
- ah5410p000101a
- ar0110p2405rt
- ar0110p2405rtb
- ar1322p1202rt
- ar5410p0003rt
- ar6230p2400rt
- ar8840p1000rt
- as0000z001101a Kίνδυνος τραυματισμού εξαιτίας συσφίξεως ή συνθλίψεως των δακτύλων κατά την εξαγωγή και τοποθέτηση και κατά τις εργασίες ρυθμίσε�
- as5410z000101a Κίνδυνος πυρκαγιάς/έκρηξης από βραχυκύκλωμα και διαφυγόν εκρηκτικό αέριο. Κίνδυνος εγκαύματος/τραυματισμού λόγω εγκαύματος στα �
- gf0510p780101a Εντατήρας καδένας Δομή