SM14.40-B-0015A | Checking the components of the SCR system air unit | 15.02.16 |
MODEL 693, 694, 695, 958, 979 with CODE (MS5) BlueTec5
B14.40-0102-01
SCR system air control unit
Represented in the models WITHOUT CODE (E30) battery master switch
Y106.1 Air control unit 30.09
1 Electric connector (Y106.1)
2 Air supply
3 Connection (straight) VOSS 232
4 Air outlet
5 "L" connection VOSS 232
6 Bolts
B14.40-0101-01
Represented in the models WITH CODE (E30) battery master switch
Y106 Electropneumatic valve (Normally open)
Y128 Electropneumatic valve (Normally closed)
8.01 Limiting valve
30.03 Pressure regulating valve
1 Electric connector (Y106.)
2 Electric connector (Y123.)
Check | |||
1 | Check the components installed in the SCR system air control unit | Check for the correct assembly of the air control unit components WITH or WITHOUT CODE (E30) battery master switch. In the case of retrofitting the battery master switch, follow the instructions starting from work step 2. | |
2 | Switch off the vehicle | ||
3 | Disconnect the battery lead | ||
REMOVAL | |||
4 | Remove the connector (1) from the air control unit (Y106.1) | ||
5 | Remove the air supply and outlet connections (3, 5) of the air control unit (Y106.1) | ||
6 | Loosen the bolts (6) and remove the air control unit (Y106.1) | ||
Installing | |||
7 | Retrofit the battery master switch | Vehicles WITHOUT CODE (E30) battery master switch. | |
8 | Retrofitting an additional compressed air reservoir | ||
9 | Pre-assembling and installing the compressed air control unit | ||
10 | Preparing and connecting electric wiring harness of the SCR system air unit | ||
11 | Manufacturing a compressed air supply pipe and connecting it | ||
12 | Requesting adaptation of parameters | Vehicles WITHOUT CODE (E30) battery master switch. | |
13 | Modifying the parameters of the control module (FR/CPC) when installing the master switch | Parameterize the module through the "Xentry Flash" | |
14 | Parameterizing the control module "MR" | Parameterize the module through the "ProParts" |
Referenzierte Dokumente
- an5410b0003a Batterietrennschalter nachträglich einbauen
- ar5410b0003a Masseleitung der Batterie ab-, anschließen
- ar5421b0420b Steuergeräte über On-/Offline-Prozess parametrieren
- sm1440b001501a Druckluftbehälter der Freiblasfunktion vormontieren und einbauen
- sm1440b001502a Druckluftsteuereinheit vormontieren und einbauen
- sm1440b001503a
- sm1440b001504a
- sm1440b001505a