ra8304d100202x

1002 - 02. Function test using a tester T1, models 601, 602 with auxiliary heater DBW 2010

Typ ra · Thema 83.70 · Version 9303 · 1993-01-15

Gültig für:

Nicht verfügbar in „de“; angezeigt wird Englisch.

Einordnung

Funktionsgruppe 3 Aufbau › 83 Klimatisierung › 83.70 Standheizung, Zusatzheizung, Zuheizer — Baureihe 601 (Baumuster 37*, 47*) · Baureihe 602 (Baumuster 37*, 38*, 462, 47*, 48*)

83-1002.02 Function test with tester

DBW 2010 only

Commercially available tools

Order no.

Company

Tester

440.280

Webasto

Kraillinger Straße 5

8035 Stockdorf

1002 - 02. Function test using a tester                                         
	T1, models 601, 602 with auxiliary heater DBW 2010

Testing with test equipment

-------------------------------

1 Connect tester (3) to harness in place of the control unit.

Note

Combustion mode is possible with the tester.

1002 - 02. Function test using a tester                                         
	T1, models 601, 602 with auxiliary heater DBW 2010

Legend for Webasto tester

1 "Battery" LED

2 "Control thermostat" LED

3 "Flame monitor" LED

4 "Circulation pump" switch

5 "Motor" switch

6 "Spark generator" button

7 "Solenoid valve" button

Test instructions

Test steps

Operation/requirement

Test result

Remedy

1

Install tester.

"Battery" LED (1) comes on.
If not:

- Check voltage on tester plug B,
terminal 4.

- Check, replace fuse F1.

- Check continuity of cable.

2

Switch on heater unit at the timer or at switch.

"Control thermostat" LED (2) comes on.

If not:

- Check, replace fuse F2.

- Check, replace diodes V1/V2.

- Check continuity of cables.

- Check, replace timer A1 or continuous operation switch S1.

3

Press "solenoid valve" button (7).

Clattering noise of solenoid valve in heater unit is audible.
If not:

- Press reset button on thermal cut-out B2.

- Check, replace thermal fuse F5.

- Check continuity of cable.

- Check, replace solenoid valve Y2.

4

Press "spark generator" button (6).

Spark must flash over audibly in heater unit.

If not:

Open burner top:

- Set electrode gap with test gauge.

- Check, replace spark generator A3.

5

Switch on "circulation pump" switch (4).

Circulation pump operates
If not:

Check, replace motor and cables.

6

Switch on "motor" switch (5).

Motor in heater unit operates.

If not:

Check, replace motor and cables.

Test steps

Operation/requirement

Test result

Remedy

7

1. Switch on "circulation

pump" switch (4).

2. Switch on "motor" switch

(5).

3. Press "spark generator"

button (6).

4. Press "solenoid valve"

button (7).

Combustion starts
"Flame" LED (3) comes on after 1-2 seconds.

If not:

Note

After combustion has started, release "spark generator" button (6).

Test flame monitor B1 with ohmmeter:
Light resistor approx.

300 W
Dark resistor > 100 kW

8

After approx. 15 seconds release "solenoid valve" button (7).

Combustion ceases immediately.

If not:

Check, replace solenoid valve Y2.

9

Open burner top:

- Switch on "engine" switch (5).

- Press "solenoid valve" button (7).

Fuel sprays evenly out of nozzle.

If not:

- Check quantity in tank, filter and fuel lines.

- Check, replace fuel pump.

- Check, replace atomizer nozzle.

Note

If combustion only took place when using the tester, the control unit is defective.

Referenzierte Dokumente