AD07.15-B-7001-08D | Low-pressure fuel circuit leaktightness, MR (PLD) hydraulic testing |
| Test of | Test instrument/test connection | Operation/ Requirement | Specified value | Possible cause/Remedy |
1.0 | Check low pressure fuel de combustible circuit for signs of leaks Attach testing and measuring equipment to low pressure fuel circuit | | Fill low pressure fuel circuit in engine with compressed air Testing pressure 10 bar: Testing time 5 min. | 0,25 bar | for larger pressure drops or fuel in engine oil |