715 589 01 63 00
Base bracket
W26.10-1122-12
The supporting plate with manufacturing date as far as 09.2006 must be re-worked. The new supporting plates are already supplied with modifications.
1 Remove supporting plate (1) pipe (2).
W26.10-1123-12
2 Make the hole (a) according to the project, on the supporting plate (1).
Hole measures
a Ø 12 mm
b 130 mm
c 60 mm
W26.10-1124-12
3 The pipe (2) removed must be shortened according to measure (j).
4 Manufacture the plate in flat steel (3) according to project.
5 Weld the shortened pipe (2) on a flat steel plate (3) according.
Pipe measure (2)
J 58 mm
Steel plate measures (3)
D 80 mm
F 50 mm
G 25 mm
H 100 mm
I Ø 12 mm
K 8 mm
Pipe measures (2) on steel plate (3)
E 30 mm
G 25 mm
L Ø 50 mm
W26.10-1125-12
6 Install steel plate (3) with screw (M12x30) and nut (4) on supporting plate (1).
Tighten nut (4) manually because during the repair, welded pipe (2) will be used in several positions on supporting plate (1).