Subsequently connect and install digital tachograph (DTCO), 2nd generation
Type sm · emne 54.61 · version 0100 · 2019-05-15
Gælder for: Model 907, 910 with code JD2 (Tachograph digital EC with rpm + aux-recorder) Model 907, 910 with code JV6 (Tachograph pre-installation kit)
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 2 Chassis › 54 El-system, udrustning og instrumenter › 54.61 Speedometer, fartskriver, taxameter — Serie 907 · Serie 910
EinPAS 31 Kommunikation/information/underholdning › 31.35 Fartskriver/betalingssystem › 31.35.3 eftermontering/ombygning — Serie 907 · Serie 910
EinPAS 45 Data/information › 45.20 Oplysninger/arbejde › 45.20.40 Servicearbejde — Serie 907 · Serie 910
SM54.61-D-0005-02TS
Subsequently connect and install digital tachograph (DTCO), 2nd generation
Topical note
Information on preventing damage to electronic components due to electrostatic discharge
with code JD2 (Tachograph digital EC with rpm + aux-recorder)
Model
907, 910
with code JV6 (Tachograph pre-installation kit)
D54.61-A010-08
Shown on model 907 with code FF8 (1-DIN slot at front under roof lining)
1
Route electric lines (2) and antenna line (3) outward as shown.
This makes it easier to connect the electric lines (2) and antenna line (3).
2
Connect electric lines (2) and antenna line (3) to 2nd generation digital tachograph (DTCO) (1).
3
Install 2nd generation DTCO (1) into device installation frame (4).
Ensure that no electric lines or component parts are damaged when inserting 2nd generation DTCO (1). Otherwise, this can lead to 2nd generation DTCO (1) malfunctions, among other things.
Insert 2nd generation DTCO (1) until it engages audibly.
Henviste dokumenter
ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund
af elektrostatisk afladning
ah6800n000101s Oplysninger om udførelse af reparationsarbejde i kabinen