PE83.30-D-2001-60P | Legend of wiring diagram for climate control | MODEL 903.663 MODEL 904.663 MODEL 903.662 /663 /672 /673 MODEL 903.662 /663 /672 /673 MODEL 903.672 MODEL 904.663 |
Code | Designation | Coordinates |
A200 | Thermotronic control unit | 11L |
B138 | Temperature sensor | 8L |
B138x1 | Temperature sensor connector | 8H |
E90 | Warm water additional heater control unit | 28L |
F23B | Fuse (50 A) for air conditioning, tml. 30 | 35G |
F30B | Fuse (25/30 A) for condenser relay, tml. 30 | 20F |
F31B | Fuse (7.5 A) for air conditioning compressor clutch relay, tml. 30 | 13F |
F32B | Fuse (7.5/20 A), tml. 30 | 24F |
F42B | Fuse (10 A) for front end blower relay (stage 1) | 33F |
F98 | Warm water heater stage 1 blower fuse (10 A) | 30G |
J16 | Tml. 30 connector sleeve | 27L |
J19 | Tml. 61 connector sleeve | 2G |
J46 | Tml. 58 connector sleeve | 5G |
J337 | ATA [EDW] blower stage connector sleeve | 29G |
K38B | Air conditioning compressor clutch relay | 14L |
K39B | Condenser relay | 21L |
K48B | Air conditioning switch relay | 25L |
K49B | Front end blower relay (stage 1) | 33L |
K75 | Fan stage 1 warm water heater relay | 30L |
M9B | Condenser | 23L |
S39B | Air conditioning switch (ON-OFF) | 2L |
S41B | Evaporator temperature switch | 17L |
S42B | Low pressure/high pressure switch | 19L |
S138 | Temperature switch | 6L |
W5 | Ground point seat frame | 30G |
W8 | Ground point waistrail | 3G |
X165 | Warm water additional heater connector 8-pin | 27G |
X195 | Frame/engine connector | 15H |
Y38 | AC compressor clutch | 16L |