gf8370w2000a

"Start heater operation" function

Type gf · emne 83.70 · version 0102 · 1999-11-08

Gælder for: MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W '

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 950 · Serie 952 · Serie 953 · Serie 954

GF83.70-W-2000A

"Start heater operation" function

30.8.96

MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W

"Start heater operation" function

W83.70-0017-09

1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor

V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel

8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel

Function sequence "Start heater operation"

The auxiliary heater can be started manually with the timer (1) for the auxiliary heater or switched on automatically by the timer when set.

The combustion air blower (11), the coolant circulation pump (8) and glow pin (3) are started.

After a preliminary delay the fuel metering pump (14) is also started.

A fuel/air mixture is then formed, which ignites on the glow pin.

The control module (2) checks formation of the flame in the burner (5) with the aid of the flame monitor (10).

As soon as a stable flame has formed in the burner, the heat output is switched to the maximum stage (power).

The coolant is heated in the heat exchanger (6) and the coolant temperature increases.

As the coolant temperature reaches the temperature thresholds the heater output is reduced in increments.

The coolant reaches the maximum temperature.

The control module switches the heater to the cooling phase with shut-off delay and then to the controlled shut-off phase.

"Start heater operation, cold start", function

GF83.70-W-3027A

"Start heater operation, warm start", function

GF83.70-W-3028A

"Start heater operation, heat consumption greater than heat output", function

GF83.70-W-3029A

Henviste dokumenter