gf8370p3063b

Ending heating mode in combustion phase, function

Type gf · emne 83.70 · version 0101 · 1999-09-15

Gælder for: MODEL 129 as of 1.6.97 with CODE (228) Stationary heater

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 129

GF83.70-P-3063B

Ending heating mode in combustion phase, function

8.7.97

MODEL 129 as of 1.6.97 with CODE (228) Stationary heater

Ending heating mode in combustion phase, function

P83.70-0394-09

1 Burner housing

2 Heat exchanger

3 Heater circuit thermostat

B Thermostat setting, auxiliary circuit open

A6m1 Circulation pump

A6n1 Stationary heater control module

N34 Stationary heater timer

Function sequence

1 Coolant temperature > 59 °C:
The thermostat (3) is set to heating, the stationary heater auxiliary circuit is connected to the vehicle cooling and heating circuit.

2 The heater is in the combustion pause. The circulation pump (A6m1) and the vehicle heater blower run.

3 Heater operation is terminated manually or automatically.

4 The circulation pump and the vehicle heater blower switch off.

5 The green indicator lamp on the stationary heater timer (N34) goes out, the heater operation stops.

Burner housing, location/purpose/design

GF83.70-P-4000A

Heat exchanger, location/purpose/design

GF83.70-P-4001A

Stationary heater/heater booster control module, location/purpose

GF83.70-P-4002A

Circulation pump, location/purpose

GF83.70-P-4003A

Stationary heater timer, location/purpose/function

GF83.70-P-4007A

Heater circuit thermostat, location/purpose

GF83.70-P-4051A