gf8260p5000ca

Media interface control unit, component description

Type gf · emne 82.60 · version 0104 · 2012-03-29

Gælder for: MODEL 207 with CODE (518) Media interface up to model year 2013 /YoM 12

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 82 El-system, karrosseri › 82.60 Radio, audio-video — Serie 207

GF82.60-P-5000CA

Media interface control unit, component description

5.3.12

MODEL 207
with CODE (518) Media interface
up to model year 2013
/YoM 12

Media interface control unit, component description

P82.60-6803-06

Illustrated on model 207.3

N125/1 Media interface control unit

Location

The media interface control unit is located behind the glove compartment.

Task

The media interface control unit is responsible for the following tasks:

Reading in of signals

Transmit signals

Reading in of signals

Signals are read in via the following connections:

Direct lines

Media Oriented System Transport (MOST)

Direct lines

The following signals are read in via direct lines:

- Audio signals and data via the media interface electrical connector (X18/70) and the "Mitsumi CAM62" connector

- Electronic wake-up for MOST

Media Oriented System Transport (MOST)

The following signals are read in via MOST:

- Control and operating signals from the audio equipment

Transmit signals

The signals are transmitted via the following connections:

Direct lines

MOST

Direct line

The media interface control unit transmits the following signals:

- General information on power supply to media interface electrical connector and to universal serial bus (USB) via "Mitsumi CAM62" connector

- Control signals to media interface connector over "Mitsumi CAM62" connector

MOST

The media interface control unit transmits audio signals and data and control signals via MOST to the audio equipment.

Technical data

Designation

Unit

Values

Tolerance range

Remarks

Media interface control unit

Power supply

V

12

-

Operating voltage UB

Voltage limits

V

>9

-

Minimum UBmin

< 16

-

Maximum UBmax

Power consumption

mA

300

-

Standby IB

mA

300

-

Typical action IAction

A

1.5

-

Maximum IAction

mA

0.1

-

Quiescent current

Reverse polarity protection

-

-

-

In range - 9... - 16 V

Flash capability/coding capability

-

-

-

DC-compatible/no

Wiring diagram for media interface control unit

N125/1

PE82.60-P-2105EAA