gf7720p3003s

Desynchronize sliding/pop-up roof, function

Type gf · emne 77.20 · version 0104 · 2003-06-12

Gælder for: MODEL 215.3 MODEL 220.0 /1 with CODE (414a) Electric glass sliding/pop-up roof MODEL 220.0 /1 with CODE (491) USA version MODEL 220.075 /175 with CODE (498) Japanese version

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 77 Soltag, kaleche, opsats › 77.20 Soltag elektrisk — Serie 215 (modeller 3**) · Serie 220 (modeller 0**, 075, 1**, 175)

GF77.20-P-3003S

Desynchronize sliding/pop-up roof, function

25.3.98

MODEL 215.3

MODEL 220.0 /1 with CODE (414a) Electric glass sliding/pop-up roof

MODEL 220.0 /1 with CODE (491) USA version

MODEL 220.075 /175 with CODE (498) Japanese version

Definition

Desychronization makes the counter status for the position measurement invalid.

Function

Desynchronization occurs when:

The overhead control panel control module (N70) has been separated from the power supply (e.g. by disconnecting the battery, removing and installing the control module) or

an error is recognized in the position measurement or

a lock-up of the drive is recognized or

the sliding/pop-up roof (SR) (M12) is moved manually (e.g. with steel crank) or

a defective excessive force limiter is recognized

In all these cases, the relationship between the counter status in the overhead control panel control module (N70) and the actual position of the sliding/pop-up roof (SR) (M12) is no longer correct.For this reason synchronization is required.

In the desynchronized state operation of the sliding/pop-up roof (SR) (M12) is limited.

It is then only possible to open the sliding/pop-up roof, whereby actuation of the SR motor (M12m1) is only possible for a short time, max. 1 s. For further actuation the switch must be released and actuated again

Synchronize sliding/pop-up roof, function

GF77.20-P-3002S

Sliding/pop-up roof lock-up recognition, function

GF77.20-P-3000S

Sliding/pop-up roof position measurement, function

GF77.20-P-3001A

Sliding/pop-up roof obstruction sensor, function

GF77.20-P-3004S

Sliding/pop-up roof, location/purpose/design/

GF77.20-P-4100S

Overhead control panel control module

location/purpose/design/function

GF82.20-P-4101S

Henviste dokumenter