gf4770p9894a

DC charge connection unit, basic function

Type gf · emne 47.70 · version 0102 · 2020-06-22

Gælder for: Model all (CAR) with code 83B (DC charging function)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 47 Brændstofsystem, energiforsyning drivline › 47.70 Energiforsyning drivline — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

EinPAS 16 Brændstof-/energiforsyning motor › 16.20 Bilens højspændingsnet › 16.20.30 Oplader/ladekabel/ladesystem — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

Gælder også for motorer/gearkasser: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

GF47.70-P-9894A

DC charge connection unit, basic function

04.06.2020

Model

all (CAR)

with code 83B (DC charging function)

Task

The DC current charge-connection unit monitors and controls the charging process of the high-voltage battery when connected to an external DC-voltage source (e. g. charging station).

The DC current charge-connection unit is connected to the network architecture of the vehicle.

Once the vehicle socket is connected with the voltage source, the DC current charge-connection unit communicates via a control line (Control Pilot) with the control box in the charging cable and/or with the charging station. In this connection, the output data of the voltage source are transmitted and the power consumption of the DC current charge-communication unit is accordingly adjusted. It is only then that the DC current charge-connection unit initiates the charging process.

The high-voltage battery can only be charged via the DC current charge-connection unit if a voltage source with direct voltage is available.

The DC current charge-connection unit processes amongst other things the following information:

Circuit status

high-voltage battery current

High-voltage battery voltage

Current/voltage request

Lock/unlock socket flap request

Lock/unlock charging cable socket request

Battery disconnect switch status

Engine running status (hybrid vehicles)

The DC current charge-connection unit processes these input factors and transmits amongst other things the following information:

Charging voltage

Charging current

DC current charge-connection unit status

Charging cable status (plugged in, not plugged in)

Control Pilot status

Socket flap status

Charging cable socket lock status

Fault messages