gf0850p1100a

High-voltage battery low-temperature circuit, detailed information

Type gf · emne 08.50 · version 0102 · 2020-01-29

Gælder for: Model 293 with code ME01 (Electric motor)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 08 Elektrodrivmekanisme, hybriddrivmekanisme › 08.50 Temperaturstyring — Serie 293

GF08.50-P-1100A

High-voltage battery low-temperature circuit, detailed information

27.01.2020

Model

293

with code ME01 (Electric motor)

High-voltage battery low-temperature circuit, detailed information

P08.50-0001-78

Schematic diagram of the high-voltage battery low-temperature circuit (low-temperature circuit 2)

1

Low-temperature circuit 2 cooler

9

Upper air regulation system control unit

2

Heat exchanger

10

Lower air regulation system control unit

3

Low-temperature circuit 2 expansion reservoir

11

High-voltage battery cooling system switchover valve

4

High-voltage PTC heater

A

Coolant warmed

5

High-voltage battery

B

Coolant cooled

6

Low-temperature coolant circuit 2 temperature sensor

C

Refrigerant (high pressure, liquid)

7

Fan motor

D

Refrigerant (low pressure, gaseous)

8

Low-temperature circuit coolant circulation pump 2