gf0717w220002a

Function of electrical-pneumatic converter (EPW)

Type gf · emne 07.17 · version 0103 · 2006-12-22

Gælder for: ENGINE 457.9 in MODEL 374, 375, 940, 942, 943, 944, 958 with CODE (MZ4) Turbobrake

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.17 Trykomformer, trykregulator — Serie 374 · Serie 375 · Serie 940 · Serie 942 · Serie 943 · Serie 944 · Serie 958

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.31 Servomotor/indstillingsled/blandingsregulator — Serie 374 · Serie 375 · Serie 940 · Serie 942 · Serie 943 · Serie 944 · Serie 958

Gælder også for motorer/gearkasser: 457 9**

GF07.17-W-2200-02A

Function of electrical-pneumatic converter (EPW)

Function of electrical-pneumatic converter (EPW)

W07.17-1004-12

1 Blow-off element control line

6 Valve

7 Pressure sensor

8 Regulating electronics

9 Solenoid proportional-control valve

Y87 Electric-pneumatic converter (EPW)

The electric-pneumatic converter (EPW) (Y87) modulates pressure according to the modulated input signal (specified value from the control unit of the engine control (MR)) in the blow-off element control line (1).
The regulating electronics (8) compares the specified value with the pressure in the blow-off element control line(1).

The pressure in the blow-off element control line (1) is measured by the pressure sensor (7).

One of the regulated quantities generated by the regulating electronics (8) actuates the valve (6) for admitting and removing air with the proportional magnets (9) till the required pressure in the blow-off element control line (1) is set.