P09.40-2210-09
1 Bolt
2 Bolt
4 Turbocharger support brace
3 Turbocharger
Bolt for turbocharger support brace altered
The factory installed bolt (1), Innentorx, must in the case of servicing be replaced after removal by bolt (2), M616 mm external Torx X. On renewed installation of the bolt (1) it is not possible to achieve the prescribed tightening torque since the bolt (1) cannot be reached with the respective tool.
The change improves accessibility to the bolt (2) and the bolt (2) can now be tightened to the required torque.