az8370w000201b

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

Type az · emne 83.70 · version 0200 · 2006-09-13

Gælder for: BODY 940.899 with CODE (F04) Cab L (long) BODY 940.899 with CODE (DD5) Cab with high roof BODY 972.899 with CODE (F04) Cab L (long) BODY 972.899 with CODE (DD5) Cab with high roof

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 940 (modeller 899) · Serie 972 (modeller 899)

EinPAS 39 Varmesystem/ventilation/køling › 39.25 Parkeringsvarme/ekstra varmesystem › 39.25.3 eftermontering/ombygning — Serie 940 (modeller 899) · Serie 972 (modeller 899)

AZ83.70-W-0002-01B

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

Modification notes

14.8.06

Drill bore (4) for fuel connection from
Ø 7.5 mm to Ø 18 mm, added.

Step 6

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

W83.70-0186-01

1 Scribe the bore markings (1 and 2) as shown onto the cab floor, in the stowage compartment behind the driver seat, and make two bores with Ø 12 mm.

a 210 MM

b 55 MM

c 270 MM

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

W83.70-0187-01

2 Affix flat drawing tool to the bores using the two tensioning bolts and then tighten the tensioning bolts.

3 Using the bolted on flat drawing tool make 4 bores Ø 7.5 mm (3) for the heater attachment and 1 bore Ø 7.5 mm (4) for the fuel connection at the engine tunnel.

4 Remove the flat drawing tool.

5 Drill the two bores for the tensioning bolts for the exhaust line and the combustion air intake line from Ø 12 mm to Ø 26 mm.

6 Drill bore (4) for fuel connection from Ø 7.5 mm to Ø 18 mm.

7 Deburr all holes and treat with corrosion protection.

8 Place floor covering back onto the cab floor and cut out in area of bores to match the contour of the heater flange.

To mark the surface of the cut, push through the floor covering at the fastening holes from below. Remove the preassembled flange gasket from the heater unit and use as a template.