ar9720s1500c

Cavity preservation following repair work

Type ar · emne 97.20 · version 0103 · 2020-03-16

Gælder for: Model 415

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 97 Karrosseritætning, korrosionsbeskyttelse › 97.20 Konservering — Serie 415

EinPAS 40 Konservering/lakering › 40.20 Korrosionsbeskyttelse › 40.20.40 Hulrumskonservering — Serie 415

AR97.20-S-1500C

Cavity preservation following repair work

09.03.2020

Model

415

Cavity preservation following repair work

We differentiate between two types of cavity preservation:

A

Cavity preservation in bead area

B

Inner surface, cavities and gaps

P97.20-2542-01

Cavity preservation following repair work

Engine hood

S97.20-4508-05

Cavity preservation following repair work

Liftgate

S97.20-4509-11

Cavity preservation following repair work

Left rear door

S97.20-4510-12

Cavity preservation following repair work

Right rear door

S97.20-4511-03

Cavity preservation following repair work

Front door

S97.20-4512-11

Cavity preservation following repair work

Sliding door

S97.20-4513-03

Cavity preservation following repair work

Front longitudinal member

S97.20-4514-11

Cavity preservation following repair work

S97.20-4515-09

Upper front longitudinal member, A-pillar,m side wall paneling, lower side longitudinal member

Cavity preservation following repair work

S97.20-4516-09

Upper front longitudinal member, A-pillar, B-pillar, side wall paneling, right lower side longitudinal member

Cavity preservation following repair work

Rear end

S97.20-4517-06

Cavity preservation following repair work

S97.20-4518-09

Underbody

Picture no., etc.

Work notes

Danger

Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when working with anticorrosion agents

Never spray corrosion protection on flames or hot, glowing objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection.

AS97.00-Z-0001-01A

Topical note

Notes on cavity preservation

AH97.20-P-0001-01B

A

Cavity preservation in bead area

Apply from inside with hook nozzle. Apply cavity preservation with spraying hose and nozzle (spraying angle 360°) as far as possible into cavities.

Cavity preservation (free of solvents), 1 liter

*BR00.45-Z-1003-05A

B

Inner surface, cavities and gaps

Uniformly moisten with cavity preservation.

Repair materials

Number

Designation

Order number

BR00.45-Z-1003-05A

Cavity preservation (free of solvents), 1 liter

A 000 986 72 70 10

Henviste dokumenter