ar9720p1500pb

Cavity preservation following repair work

Type ar · emne 97.20 · version 0107 · 2011-11-24

Gælder for: MODEL 203.7

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 97 Karrosseritætning, korrosionsbeskyttelse › 97.20 Konservering — Serie 203 (modeller 7**)

EinPAS 40 Konservering/lakering › 40.20 Korrosionsbeskyttelse › 40.20.40 Hulrumskonservering — Serie 203 (modeller 7**)

AR97.20-P-1500PB

Cavity preservation following repair work

15.11.11

MODEL 203.7

Cavity preservation following repair work
Cavity preservation following repair work

P97.20-2136-01

Engine hood

Front wheel well

P97.20-2137-01

Cavity preservation following repair work

P97.20-2138-09

Longitudinal member left and right rear wheel well

Cavity preservation following repair work

P97.20-2141-09

Longitudinal member front end and underbody

Cavity preservation following repair work

P97.20-2152-11

Door

Cavity preservation following repair work

P97.20-2153-09

Cross member above rear axle and liftgate

Cavity preservation following repair work

P63.20-2895-06

Openings for cavity preservation

A Cavity preservation opening
(upper outer B-pillar reinforcement)

B Cavity preservation opening
(center outer B-pillar reinforcement)

C Cavity preservation opening
(outer reinforcement)

Danger!

Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when handling anticorrosion agents.

Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection.

AS97.00-Z-0001-01A

Notes on cavity preservation

AH97.20-P-0001-01B

Processing instructions for cavity preservation agent

AP97.20-P-0640-01A

Cavity protection, general

GF98.00-P-2045A

1

Perform repair preservation

Apply preservation agent from inside in marked areas following sealing and paintwork, however, before performing assembly work

The processing temperature should not be less than 15 °C.

Additional preservation measures may be required, depending on the repair area, deviating from the standard cavity preservation shown.

The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. The cavities should be dry. Insert spray hoses as far as possible into hollow cavities. Spray while inserting and pulling out slowly.

Apply repair preservation agent twice after a drying time of 5 minutes in between.

After replacing B-pillar, supplement cavity preservation through cavity preservation openings (A, B, C).

Combination pressure spray gun (corrosion protection)
gotis://K_91-97_01.0

Preservation agent

*BR00.45-Z-1003-05A

2

Remove cavity sealant from drain holes

Repair materials

Number

Designation

Order number

BR00.45-Z-1003-05A

Cavity sealant, solvent-free (1 l container)

A 000 986 72 70 05

Henviste dokumenter