ar9720p1500ew

Cavity preservation following repair work

Type ar · emne 97.20 · version 0104 · 2010-08-04

Gælder for: MODEL 212.0/ 1

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 97 Karrosseritætning, korrosionsbeskyttelse › 97.20 Konservering — Serie 212 (modeller 0**, 1**)

EinPAS 40 Konservering/lakering › 40.20 Korrosionsbeskyttelse › 40.20.40 Hulrumskonservering — Serie 212 (modeller 0**, 1**)

AR97.20-P-1500EW

Cavity preservation following repair work

27.7.10

MODEL 212.0/ 1

Cavity preservation following repair work

P97.20-2526-11

Engine hood

Cavity preservation following repair work

P97.20-2525-11

Liftgate

Cavity preservation following repair work

P97.20-2524-11

Front door

Cavity preservation following repair work

P97.20-2518-11

Rear door

Cavity preservation following repair work

P97.20-2523-09

Upper front longitudinal member, A-pillar, B-pillar, C-pillar, side wall paneling and bottom side longitudinal member

Cavity preservation following repair work

P97.20-2522-11

Front longitudinal member

Cavity preservation following repair work

P97.20-2519-05

Rear longitudinal member

Cavity preservation following repair work

P97.20-2520-11

Rear end

Cavity preservation following repair work

P97.20-2521-09

Underfloor

Danger!

Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when handling anticorrosion agents.

Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection.

AS97.00-Z-0001-01A

Notes on cavity preservation

AH97.20-P-0001-01B

1

Perform repair preservation

Apply cavity sealant from inside in crosshatched areas following sealing and paintwork, however, before performing assembly work. Apply repair preservation agent twice with a drying time of 5 minutes in between.

The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. The cavities should be dry.

Insert spray hoses as far as possible into cavities. Spray while inserting and pulling out slowly.

Processing instructions for cavity preservation agent

AP97.20-P-0640-01A

Cavity protection, general

GF98.00-P-2045A

Preservation agent

*BR00.45-Z-1003-05A

2

Remove cavity sealant from drain holes

The processing temperature should not be less than 15 °C. Additional preservation measures may be required, depending on the repair area, deviating from the standard cavity preservation shown.

Repair materials

Number

Designation

Order number

BR00.45-Z-1003-05A

Cavity preservation, solvent-free (1 l container)

A 000 986 72 70 05

Henviste dokumenter