P91.60-4550-08
1 | Glove compartment | 4 | Bracket | |
2 | Front passenger airbag | 5 | Bolt | |
3 | Nuts |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch on ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Disconnect ground line to battery | ||
3 | Remove glove compartment (1) | ||
4 | Cover door sill and door sill molding with door sill protector | ||
| 000 588 08 98 00 Cover | ||
5 | Remove right A-pillar paneling | ||
6 | Unscrew bolt (5) from instrument panel | ||
7 | Release and disconnect electrical connectors (arrow A) from front passenger airbag (2) | ||
8 | Release and disconnect electrical connectors (arrows B) from front passenger airbag (2) | ||
9 | Unscrew nuts (3) | Nut, front passenger airbag unit to instrument panel | |
10 | Lift instrument panel with assistant far enough to enable the front passenger airbag (2) to be removed | | |
11 | Remove front passenger airbag (2) together with bracket (4) | ||
12 | Install in the reverse order | ||
| Check | ||
13 | Check and erase vehicle fault memory using diagnostic system | When replacing front passenger airbag (2). | |
|
Henviste dokumenter
- ad0000p200004b
- ah0000n000101a Oplysninger om selvlåsende bolte og møtrikker
- ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund af elektrostatisk afladning
- ah9100z000010a Oplysninger, bedømmelser og lovmæssige bestemmelser vedrørende arbejde, håndtering og opbevaring af pyrotekniske komponenter
- ar5410p0003lf Afbrydelse, tilslutning af batteriets stelledning
- ar6810p1400lf
- ar6830p4050lf
- as9100z000801a Fare for personskade ved kontrol- og reparationsarbejde i forbindelse med pyrotekniske komponenter
- ws9800p0014b