ar9160d061104a

Operating the deployment device

Type ar · emne 91.60 · version 0101 · 2011-07-08

Gælder for: MODEL 900, 901, 902, 903, 904, 905, 906 Nicht für gültig'

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 91 Sæder, køjer, selestrammere › 91.60 Airbag, fodgængerbeskyttelse — Serie 900 · Serie 901 · Serie 902 · Serie 903 · Serie 904 · Serie 905 · Serie 906

EinPAS 27 Passive sikkerhedssystemer › 27.16 Airbag › 27.16.20 Airbag — Serie 900 · Serie 901 · Serie 902 · Serie 903 · Serie 904 · Serie 905 · Serie 906

AR91.60-D-0611-04A

Operating the deployment device

Danger!

Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.

Store airbag unit with deployment face up, do not subject to temperatures above 100 °C. When working on these units, disconnect the power supply.

AS91.00-Z-0001-01A

Operating the deployment device

Ignition device

126 589 00 90 00

For testing arrangement, turn rotary switch of deployment device to position

Cable set plug, no.

Up to 6/93

Cable set plug, no.

from 7/93

Test of

Press:

Buttons

Specified value:

LED

Possible causes for deviation from specified value

1

Internal battery test

Press

Deployment device not connected

ON

Green

Indicator lamp ON

Replace ignition device battery set if necessary:
2 baby cells

(21.5 V)

1

3+4

10+11

Actuation of
driver side squib

Press both pushbuttons

1. Before actuation

ON

Triggering circuit is defective

2

1+2

3+4

1+2

3+4

Ignition of emergency tensioning retractor squib, left seat

Ignition of emergency tensioning retractor squib, right seat

Press both pushbuttons

Deployment makes a bang

Triggering circuit is defective

3

5+6

13+14

Ignition

Front passenger squib

Press both pushbuttons

2. After deployment

ON

Green

Indicator lamp ON

Triggering circuit is defective