ar8610p0103mb

Remove/install extinguishing agent reservoir paneling

Type ar · emne 86.10 · version 0100 · 2004-11-29

Gælder for: MODEL 220.1 /8 with CODE (Z04) Light armoring with CODE (Z07) Top protection with fire extinguishing system

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 86 Nødudstyr, handicapvenligt udstyr, sanitært udstyr, køkken › 86.10 Nødudstyr — Serie 220 (modeller 1**, 8**)

EinPAS 27 Passive sikkerhedssystemer › 27.21 Brandslukningssystem/brandmeldesystem › 27.21.50 Beholder — Serie 220 (modeller 1**, 8**)

AR86.10-P-0103MB

Remove/install extinguishing agent reservoir paneling

22.6.04

MODEL 220.1 /8
with CODE (Z04) Light armoring
with CODE (Z07) Top protection
with fire extinguishing system

Remove/install extinguishing agent reservoir paneling

P86.10-2154-04

1 Extinguishing agent reservoir paneling

2 Expanding clip

Remove/Install

1

Open trunk lid

See Operator's Manual

2

Remove trunk floor

See Operator's Manual

3

Remove expanding clip (2).

Installation: Check expanding clip (2), replace if necessary

4

Remove extinguishing agent reservoir paneling (1)

The extinguishing agent reservoir paneling (1) can vary depending on the equipment

5

Install in the reverse order