1 | Extinguishing agent tank |
2 | Screw clamp |
3 | Union nut |
4 | Fire extinguishing pipe |
6 | Connector |
7 | Cover |
P86.10-2344-06
1 | Extinguishing agent tank |
8 | Locking pin |
9 | Valve body |
P86.10-2359-12
Topical note | Notes on squib on extinguishing agent tank | Typ 222.1 mit Code Z07 (Höchstschutz) mit Code Z21 (Feuerlöschanlage) | |
Notes on aerosol extinguishing agent tank | Typ 222.1 mit Code Z07 (Höchstschutz) mit Code Z21 (Feuerlöschanlage) | ||
| Remove | ||
1 | Switch off ignition and remove transmitter key | ||
2 | Open paneling (7) on extinguishing agent tank (1) | ||
3 | Unscrew safety pin (8) from valve body (9) | To secure extinguishing agent tank (1). | |
4 | Use safety pin (8) and screw into valve body (9) | | |
To secure extinguishing agent tank (1). | |||
Locking pin to extinguishing agent tank | |||
5 | Remove fuse 4 from fuse box I, rear right wheel well | ||
6 | Disconnect electrical connectors from extinguishing agent tank (1) | ||
Notes for extinguishing agent tank pressure monitor switch | |||
7 | Unscrew union nut (3) and carefully remove extinguishing agent pipe (4) from connector (6) on extinguishing agent tank (1) | ||
8 | Open hose clamps (2) | ||
9 | Remove extinguishing agent tank (1) | ||
| Install | ||
10 | Install extinguishing agent tank (1) in bracket | ||
11 | Close bolt clamps (2) | ||
12 | Carefully guide extinguishing agent tube (4) into connection piece (6) and tighten union nut (3) | Threaded connections for extinguishing agent lines | |
13 | Connect electrical connectors to extinguishing agent tank (1) | ||
Notes for extinguishing agent tank pressure monitor switch | |||
14 | Insert fuse 4 into fuse box i, right rear wheel arch | ||
15 | Unscrew safety pin (8) from valve body (9) | To release extinguishing agent tank (1). | |
16 | Use safety pin (8) and screw into valve body (9) | | |
To release extinguishing agent tank (1). | |||
Locking pin to extinguishing agent tank | |||
17 | Close paneling (7) on extinguishing agent tank (1) | ||
| Check | ||
18 | Perform self-test for fire extinguishing system |
Henviste dokumenter
- ah8610p000102a Oplysninger om aerosol-slukningsmiddelbeholder
- ah8610p000103a Oplysninger om kontakt trykovervågning på slukningsmiddelbeholder
- ah8610p000104a Oplysninger om tændladning på slukningsmiddelbeholder
- ar8610p010101lfs